9850060 R02 - 2020-2021 850 AXYS™ Long Track Snowmobile Service Manual
© Copyright Polaris Inc.
1.109
12. If no faults are encountered, and there is sufficient
battery voltage to proceed, the learn procedure will
commence.
NOTICE
The ECU will command the EV actuator relay to open
and close several times during the procedure. The
instrument cluster or PIDD will turn on and off each time
the relay is closed and opened. This is normal and
critical to the completing the learning procedure. The
actuator will also be heard moving back and forth as the
ECU sets the travel limits.
13. At the end of the procedure, the software will check
for any faults that may have occurred.
14. If no faults are encountered, this screen will appear
noting the procedure has successfully completed.
Press the red X button to return to the main menu.
15. If a fault were to occur, an error screen will appear
describing what the fault was and how to resolve the
issue. Typically, the fault will be caused by a partially-
charged battery or loose wire connector as noted by
this error screen.
16. If an error screen appears, charge the battery and
check for obvious mechanical issues. Check all
associated wires and wire connectors. Clicking
“CONTINUE” on the error screen will prompt the user
to either try the learn procedure again, or exit the
procedure.