9850060 R02 - 2020-2021 850 AXYS™ Long Track Snowmobile Service Manual
© Copyright Polaris Inc.
10.19
KNOCK (DET) SENSOR HARNESS ROUTING
1. The knock (DET) sensor
q
is secured to the cylinder head. Route the knock (DET) sensor harness toward the PTO
side over structure tube and pass harness in between over structure tube and main harness.
2. Secure knock (DET) sensor harness and main harness to the over structure tube with a panduit
w
.
3. Continue to route the knock (DET) sensor harness toward the PTO side of vehicle and connect the knock (DET)
sensor connector
e
to the main harness connector.
4. Secure the knock (DET) sensor connector and harness slack to the main harness with a panduit
w
as shown.
Summary of Contents for 850 PRO-RMK 155 2.6" QD 2021
Page 6: ......
Page 738: ......
Page 739: ......
Page 741: ...850 Long Track Jumper Console Switches 2413927 ...