1.78
9850060 R02 - 2020-2021 850 AXYS™ Long Track Snowmobile Service Manual
© Copyright Polaris Inc.
246
P1607
Regulator:
ECU Overload
This Trouble Code Sets if the Regulator has
detected Excessive Current Draw in the ECU
Supply Can be caused by defective power circuit
to the ECU, electrical modifications or faulty ECU
255
P1608
Regulator:
ECU Voltage
Too High
This Trouble Code Sets if the Regulator has
detected Excessive Voltage in the ECU Supply
Can be caused by damaged wiring, Regulator
connections or Regulator
32523
4
P1609
Regulator:
Critical Voltage
Too Low
This Trouble Code Sets if the Regulator has
detected Low Voltage in the Critical Circuit Can be
caused by damaged Regulator wiring or
connections, electrical modifications or faulty
Regulator
5
P160B
Regulator:
Critical Open
Circuit
This Trouble Code Sets if the Regulator has
detected an Open Circuit in the Critical Circuit
Can be caused by damaged wiring, faulty
headlight, Fuel Pump or Regulator connections
6
P160C
Regulator:
Critical Short
Circuit
This Trouble Code Sets if the Regulator has
detected Excessive Current in the Critical Circuit
Can be caused by damaged wiring, faulty
headlight, Fuel Pump or Regulator connections
15
P160D
Regulator:
Critical Voltage
Too High
This Trouble Code Sets if the Regulator has
detected Excessive Voltage in the Critical Circuit
Can be caused by damaged wiring, faulty
headlight, Fuel Pump or Regulator connections
20
P160E
Regulator:
Chassis
Voltage Too
Low
This Trouble Code Sets if the Regulator has
detected Low Voltage in the Chassis Circuit Can
be caused by damaged wiring or faulty grip
heaters
22
P160F
Regulator:
Chassis Short
Circuit
This Trouble Code Sets if the Regulator has
detected Excessive Current Draw in the Chassis
Circuit Can be caused by damaged wiring or
faulty grip heaters
31
P1610
Regulator:
Chassis
Voltage Too
High
This Trouble Code Sets if the Regulator has
detected Excessive Voltage in the Chassis Circuit
Can be caused by damaged wiring, Regulator
connections or Regulator
32531
36
P1510
Regulator:
Stator Output
Low
This Trouble Code Sets if the Regulator has
detected a Low Voltage condition in the Stator
Can be caused by a Short to ground in the Stator
or damaged Stator wiring.
37
P1511
Regulator:
Stator Open
Circuit
This Trouble Code Sets if the Regulator has
detected an Open Circuit condition in the Stator
Can be caused by an Open Circuit in the Stator or
damaged Stator wiring.
520376
31
P1618
Regulator
Chassis
Voltage
Disabled
This Trouble Code Sets if the Regulator has
detected an internal fault Can be caused by a
faulty Voltage Regulator Module
520377
31
P1619
Regulator ECU
Voltage Too
Low
This Trouble Code Sets if the Regulator has
detected an internal Low Voltage Condition Can
be caused by damaged wiring/connections or
Regulator/connections
Summary of Contents for 850 PRO-RMK 155 2.6" QD 2021
Page 6: ......
Page 738: ......
Page 739: ......
Page 741: ...850 Long Track Jumper Console Switches 2413927 ...