10.16
9850060 R02 - 2020-2021 850 AXYS™ Long Track Snowmobile Service Manual
© Copyright Polaris Inc.
RESONATOR EGT SENSOR
1. The EGT sensor
q
is connected into the top of the resonator. Route the EGT sensor wire harness up to the
plenum.
2. Secure the EGT sensor wire harness and main harness to the plenum with a routing clip
w
.
3. Route the EGT sensor wire harness rearward and connect the EGT sensor connector
e
to the main harness
connector.
4. Take up the EGT sensor wire harness slack and secure the slack, EGT sensor connector, and main harness with a
panduit strap
r
.
NOTICE
Orientation of panduit strap should be pointing down like shown.
Summary of Contents for 850 PRO-RMK 155 2.6" QD 2021
Page 6: ......
Page 738: ......
Page 739: ......
Page 741: ...850 Long Track Jumper Console Switches 2413927 ...