32
EN001 H01
Step
Action
6
Reminder
6.1
After pressing the green start button a message will remind you of your duty to fix and prepare the
pipes according to the general guidelines. If you have any doubt about the correct preparation,
you can quit the procedure by actuating the red stop button. Otherwise, confirm that you prepared
everything properly by pressing the green start button.
Reminder
7
Measuring the fitting resistance
7.1
The electrofusion control unit begins to measure the fitting resistance. Should the measured fitting
resistance be out of the valid range, an error message will be shown on the display and the error
will be indicated by a bleep. The bleep can be interrupted by pressing the red stop button.
Display when a resistance error has occurred
Row 1 shows lower and upper limit on the left and right and the measured resistance in the
middle.
Row 2 shows the nominal welding time.
Row 3 shows the report number under which the error report is stored.
Row 4 shows “Resistor Error”
7.2
Unplug the welding cable from the fitting. Check that the contacts of the fitting and the welding
terminals are clean. Should the fitting, after cleaning the contact surfaces, produce another
resistor error then it could be defective. Use another fitting.
8
No resistance error detected
8.1
The electrofusion control unit begins the welding procedure automatically if no resistance error
occurred.
Attention!
Do not touch the fitting or the contact surfaces during the welding process. Keep a minimum safe
distance of 1 m to avoid the risk of injury by molten PE mass.
Is the pipe scraped
and clamped?
0.15< 0.05 <35.00
Nom. time: 30 s
Resistance error