14
EN001 H01
7.1 Data recording Monomatic
The electrofusion control units of type Monomatic do not generate reports.
7.2 Data recording Monomatic (Bluetooth)
When using the PFS app and the connection via Bluetooth, the electrofusion control units of type Monomatic
(Bluetooth) transfer reports to the connected smartphone or tablet. An internal memory is not available in the
electrofusion control unit.
7.3 Data recording Monomatic Data USB and Monomatic Data USB
(Bluetooth)
The electrofusion control units of type Tiny Data M(F) USB (Bluetooth) provide data recording for approx.
500 welding cycles.
Monomatic Data USB
Monomatic Data USB (Bluetooth)
Data recording
Number of reports
Approx. 500
Interface
USB (USB memory stick, USB printer)
Data format
PDF, CSV
Recorded data
General data
Time, date, report number, ambient temperature
Fusion data
Voltage, current, energy, nominal and actual welding time,
mode, resistance, error messages with 10 voltage and
current values
Device data
Serial number, inventory number, date of last service,
working hours, system configuration
Additional functions
Output options
Whole memory
Job code input/selection
Manual, internal list of job numbers for selection
The given technical information is valid for the standard setup of the electrofusion control unit. Depending on the ordered