EN001 H01
23
11. Starting a welding process
The electrofusion control units Monomatic, Monomatic (Bluetooth), Monomatic Data USB and Monomatic
Data USB (Bluetooth) only offer SmartFuse as a means for input of welding parameters.
Attention!
•
The generator must be grounded!
•
If the electrofusion control unit is used on a generator which is not grounded or on
mains without protective earthing conductor there is a risk of an electric shock.
11.1 Preparation
Before starting up the following steps have to be performed in the given order:
Step
Action
1
Check the electrofusion control unit, cables and adapters optically and replace them in case of
defects or damage.
2
Fully unwind the power supply cable and the welding cable.
3
Connect the detachable welding cable to the control unit.
4
Switch off the ON-OFF-switch of the electrofusion contol unit.
5
Start the generator before plugging in the electrofusion control unit. Wait until the
generator output voltage has stabilized.
6
Plug in the power cord of the electrofusion control unit.