16
EN001 H01
Duty cycle according to ISO 12176-2 at 30 %, 60 % and 100 %, Test time t = 60 minutes
Test time
60 min
Output power
at U
OUT
= 36 V
Output power
at U
OUT
= 40 V
Output current
I
OUT
30 %
2700 W
3000 W
74.1 A
60 %
2050 W
2250 W
55.9 A
100 %
1600 W
1800 W
44.7 A
Additional Information
Soft Start
At least 3 seconds (ramp)
Ambient temperature compensation
No
Fitting temperature compensation
No
Data recording
Monomatic
Monomatic (Bluetooth)
No
Data recording
Monomatic Data USB
Monomatic Data USB (Bluetooth)
Yes
Bluetooth module
Monomatic
Monomatic Data USB
No
Bluetooth module
Monomatic (Bluetooth)
Monomatic Data USB (Bluetooth)
Bluetooth LE
The given technical information is valid for the standard setup of the electrofusion control unit. Depending on the ordered
setup there may be variations.