12
EN001 H01
7. Technical data
Monomatic / Monomatic (Bluetooth)
Monomatic Data USB / Monomatic Data USB (Bluetooth)
General
Output voltage
[V]
40 AC
Data recording
Monomatic: No
Monomatic (Bluetooth): No
Monomatic Data USB: Yes
Monomatic Data USB (Bluetooth): Yes
Power (60 % ON time)
according to ISO 12176-2
2050 W (55.9 A)
Operating temperature range
[°C]
-10 to +50
International protection
IP54
Appliance class
1
Conformity
CE
ISO 12176-2 Class - classification
Monomatic
Monomatic (Bluetooth)
P
2
3 U S
1
F A M
ISO 12176-2 Class - classification
Monomatic Data USB
Monomatic Data USB (Bluetooth)
P
2
3 U S
1
F A D M
Input of welding parameters
Ye
s
No
Opt.
Barcode with reading pen
(scanner optional)
SmartFuse
Manual input of the barcode
digits.
Manual input of welding
parameters
U
OUT
: 8 to 48 V
t
WELD
: 0 to 9999 s
Manual input of welding
parameters
U
OUT
: 40 V (preset)
t
WELD
: 0 to 9999 s