180
RS-232C Adjustment
5.5.6 QUEST Commands
What are QUEST commands?
• They are commands for outputting TXD such as adjustment data from the internal microcomputer of the plasma
display to a PC.
• Adjustment data and the like is output in ASCII code.
Note
Command names are given inside brackets < >.
• Data output format
Notes
• A QUEST command is invalid when no ID No. is assigned to the set.
• A QUEST command is invalid when a wildcard (*) is used in the ID No. when sending the command.
1) <GST> (GET STATUS)
Order
Data Contents
Size
Remarks
1
Display data
3 Byte
See below
2
Power data
3 Byte
See below (The third character is sub input.)
3
Input function data (main)
3 Byte
Input data when GST is received (INPUT1 to 5 is displayed as IN1 to 5.)
4
Input function data (sub)
3 Byte
Sub input data when GST is received
Note 3)
(INPUT 1 to 5 is displayed as IN1 to 5.)
5
Screen size data
1 Byte
See below
6
2-screen display
1 Byte
0: OFF (1 screen)
1: 2-SCREEN
2: PinP (lower right)
3: PinP (upper right) 4: PinP (upper left)
5: PinP (lower left)
6: PoutP
7
FUNCTIONAL LOCK data
1 Byte
0: LOCK OFF 1: BUTTONS LOCK 2: IR LOCK
3: IR&BUTTONS LOCK 4: MEMORY LOCK
8
Dummy data
3 Byte
(3-digit number)
9
Temperature data 2
3 Byte
(Internal temperature: Reference value) °C
Note 1)
10
Temperature data 3
3 Byte
(External temperature: Reference value) °C
Note 1)
11
Serial
15 Byte
12
Dummy data
3 Byte
(3-digit number)
13
Dummy data
3 Byte
14
HOURMETER
5 Byte
Displays the time.
15
Check sum
2 Byte
STX (02hex)
Command
(3 Byte)
Data
····
Data
ETX (03hex)
Checksum
(2 Byte)
Display data
First character Generation data: 4 (fixed)
Second character Inch data: 4 (43 inch), 5 (50 inch)
Third character Destination data: M (fixed)
Power data
First character Power state & signal state
Second character PN (POWER ON & normal signal input)
PL (POWER ON & no input)
PO (POWER ON & OUT OF RANGE signal input)
SN (Normal standby)
SW (Standby by POWER MANAGMENT)
SS (Standby by SD or PD)
Third character Sub input signal state during multi-screen display
Note 2)
N (Normal signal input) L (No input)
O (OUT OF RANGE signal input)
Screen size data
First character 0; Dot by Dot or PARTIAL 1; 4 : 3 2; FULL or FULL1080i
3; ZOOM 4;CINEMA 5;WIDE 8;FULL1035i 9; UNDERSCAN
NOTE 1) During standby and immediately after POWER ON, the proper value is not output. In this case, wait a moment
after the POWER ON, then get the data. The temperature data is output as a reference (the values are not
guaranteed values). Normally, refer to temperature data 3.
NOTE 2) During standby and during 1-screen display, dummy data (symbol) is output.
NOTE 3) During standby and during 1-screen display the values stored in memory for the product are output.