45
(2) When the plasma display is in a confined space.
Operating this display in confined spaces is not recommended.
• If the display is to be used in confined spaces, observe the following conditions shown in the drawing below in this page:
A
≥
50
• If hot air remains in the closed space, the temperature may rise, causing a malfunction or fire. As a precaution in case
of accidents, the inner wall should have sufficient heat resistance or fire resistance.
• Leave a space at least 10 mm wide when installing glass etc. on the front of the plasma display.
✩
Usage temperature conditions
• Ambient temperature: 0 °C to 35 °C (Outside air temperature)
• Space enclosed by the back surface of the plasma display: 0 °C to 35 °C (Use a fan etc. to discharge air to
maintain this temperature range.)
Special installation (Installed facing upward)
10 mm
150 mm
50 mm
A
Outside air temperature
measuring point
Outside air
temperature
measuring point
Enclosed space air temperature
measuring point
Enclosed space air
temperature measuring
point
A
≥
50
When installing the plasma display facing upwards, do not place anything on top of it nor apply any load on it from
above. This will damage it.
: Thermometer (temperature measurement point)
Note