30
3.4.2 Hanging on the wall
Carefully read the following before attempting to hang the unit on a wall, and observe the various limitations specified
below. Be sure to mount the unit so that twisting, bending, or any other deformation does not exceed 4 mm.
Shaded areas
indicate attachment points for mounting hardware.
Special Instruction (Hanging on the wall)
Operating temperature restrictions
✩
Standard single-unit installation
Distance from wall (A)
B
C
D
Ambient temperature
50 mm or less
300 mm or more
300 mm or more
300 mm or more
0 °C to 35 °C
50 mm or more
100 mm or more
50 mm or more
50 mm or more
0 °C to 40 °C
✩
Horizontal/vertical, left/right reverse installation (Note that only Examples 2 and 3 apply in cases
where top and bottom are reversed)
* No matter what the distance between the unit and the wall, the unit must be installed in such a way as
to ensure free air flow (With no obstructions within a distance of 300 mm from the unit).
Distance from wall (A)
B
C
D
Ambient temperature
50 mm or more
300 mm or more
300 mm or more
300 mm or more
0 °C to 35°C
✩
Requirements when used with PDP-S44-LR speaker system
When installed as a single unit, all requirements are the same as those listed above for horizontal/
vertical, left/right reverse installation. Note, however, that the figures listed above are to be interpreted
as indicating the distance between the speakers and the wall.
25
90
A
B
C
D
D
1022
50
Note
Different temperature restrictions apply to the PDK-5011 and PDK-WM01. Refer to “4.6 Tilt Mount Unit (pg. 64)” and
“4.7 Wall Mount Unit (pg. 72)”. In wall-mounting installation, allow adequate space (a clearance of 300 mm or more)
above and below the monitor set, as well as to the right and left.
: Thermometer (temperature measurement point)