35
Special installation (When the display is put in a box)
3.4.4 When the display is put in a box
Operating this display in confined spaces is not recommended.
• If the display is to be used in confined spaces, observe the following conditions shown in the drawing below in this page:
A
≥
50
B
≥
50
C
≥
10
D
≥
50
Use a mesh with aperture efficiency of 50 % or more.
Thus, everywhere in "Y" must be kept less than the following temperature range. If hot air remains in the closed
space, the temperature may rise, causing a malfunction or fire. As a precaution in case of accidents, the inner wall
should have sufficient heat resistance or fire resistance.
✩
Usage temperature conditions (BOX air temperature)
• Ambient temperature: 0 °C to 35 °C
Rear view (the following area should be made of mesh)
A
≥
50
B
≥
50
C
≥
10
D
≥
50
A+
50 mm
A+
50 mm
A+
50 mm
B+
50 mm
B+
30 mm
100 mm
100 mm
or more
Mesh with aperture efficiency
of 50 % or more
A+
50 mm
1118 mm or more
1118 mm or more
A
A
B
B
C
D
: Thermometer
(temperature measurement point)