Installation Conditions
3.2.4 Mounting surface warping
The display section incorporates glass. Before mounting the product, using hardware other than that provided by
Pioneer, perform the following to confirm that the display is free from warps exceeding 1 mm*.
* Regarding the 1 mm limit
The frame of the display may have a warp of up to 3 mm. If the total warp (the warp of the frame plus the warp of the
mount surface) exceeds 4 mm then the glass in the display may be put under excessive stress. In order to ensure
that the total warp is less than 4 mm, you should make sure that the warp of the mount surface is less than 1 mm.
1
Referring to the illustration below, diagonally extend string of maximum
φ
0.1- mm diameter through the bolt
mount openings. Strings thus arranged should be completely free of slack.
2
Measure the clearance (L) between the strings at their point of intersection.
Distortion is expressed by: [Distortion] = L
×
2.
3
If L is found to be 0, pass the strings through the other bolt mount openings and repeat the measurements. Any
value of L greater than 0 indicates the presence of distortion. If the measured value in both cases is 0, the
distortion is negligible.
A
B
D
F
E
C
A
Mount bolt holes
Plasma Display Mount Surface (Mount Brackets)
String
String
Magnified view of section A
Point E is the center point of string
segment A-B.
Point F is the center point of string
segment C-D.
Clearance between points E and F = L
(Points E and F are shown displaced
for illustrative purposes).