SOUTHEASTERN MEDICAL SUPPLY, INC 

 

 

 

Advanced Blood Pressure and SpO2

 

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for Combi 08A pulse

Page 1: ...SOUTHEASTERN MEDICAL SUPPLY INC Advanced Blood Pressure and SpO2 All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...Model CONTEC08A To assure the correct use of the product safety measures please carefully read user manual before using After reading please validly keeping to refer and consult at any moment All manu...

Page 3: ...curate Measurement Way 9 BP Measurement 9 Memory Function 10 Review The Memory Value 10 Delete Memory Values 11 Alarm Function 12 SPO2 Measurement Function Separate Sale 12 Monitoring Procedure 13 Mai...

Page 4: ...your physician for specific information about your blood pressure Please hand measurement results to the doctor who know your health to accept diagnosis For severe blood circulation disorder or arrhyt...

Page 5: ...re and polarities of the batteries must match the polarities of the battery compartment as indicated When the batteries power exhausts replace with four new batteries at the same time Please take out...

Page 6: ...other USB Data Line Software CD User Manual Separate Sale AC Adapter CMS0106 InputAC 100 240V 50 60Hz AC 15 0mA Output DC 6 0V 0 2V 1 0A Spo2 Probe Spo2 10UC15 Spo2 Measurement Range 35 100 Measureme...

Page 7: ...cuff The three buttons correspond with the hint in the LCD screen downside pressing any button will carry on corresponding function eg MENU ENTER LIST etc Up and down buttons respectively carry on the...

Page 8: ...he batteries according to applicable local regulations about environmental Using The AC Adapter Connect Monitor and the AC Adapter Insert the AC Adapter Plug into the AC Adapter Jack on the right side...

Page 9: ...to PC via USB and processed with the PC software If the date and time are set correctly the date and time when measuring will be correct in the memory otherwise it may not be correct Note Correctly us...

Page 10: ...tores the measure results of three users automatically and up to 100 items for every user Users can press USER button in main interface to switch user Or press USER PURVIEW item in SYSTEM SETUP menu t...

Page 11: ...the air plug is securely inserted in the main unit Stretch cuff into a barrel for the arm can conformable enter into the barrel Arm penetrate throught the cuff the air tube of the cuff will pass the...

Page 12: ...es before measurement Relax the body do not let the muscle activity Do not talk and movement during the measurement Wait 4 5 minutes between measurements Do not use a cellular phone near the device BP...

Page 13: ...turn the monitor off The monitor will automatically turn off after two minutes in which there is no operation to the device even if you forget to turn the power off Memory Function The monitor is des...

Page 14: ...ete all values stored in the memory of each user separately instead of deleting a special item 1 Press MENU button to enter SYSTEM MENU select DELETE DATA item and enter its interface in which select...

Page 15: ...bout to exhaust and alarm is on then the alarm will occur This alarm can not be cancelled unless being closed or the power replaced SPO2 Measurement Function Optional Please pay attention to Warning P...

Page 16: ...rent patients Monitoring Procedure 1 Attach the sensor to the appropriate site of the patient finger as following figure place SPO2 2 Plug the connector of the SPO2 probe cable into the USB socket in...

Page 17: ...aution Do not subject the sensor to autoclaving Do not immerse the SPO2 probe into any liquid Do not use any SPO2 probe or cable that may be damaged or deteriorated Cleaning Use a cotton ball or a sof...

Page 18: ...CD ROM in the CD ROM compartment located on your computer 2 If Auto Play for CDs is enabled place CD in reader and follow instructions when they appear in the screen otherwise follow install instruct...

Page 19: ...e the cuff plug is securely inserted in the windpipe refer to 8 page Air pressure error Air pressure error Keep arm body still measure again Weak signal The pulse signal is too weak or the cuff is loo...

Page 20: ...ply cuff It can not carry on measurement when press the measurement button Switch on the power once again and restart a measurement Power off suddenly when inflating No use for a long time the power o...

Page 21: ...rgent after the cloth can be full twisted Warning Do not submerge the device in water Advice Do not use any naphtha thinner or gas to clean Do not attempt to clean or wash the cuff Keeping Advice Do n...

Page 22: ...asurement Accuracy Cuff Pressure Accuracy 3mmHg Error The BP Value of the device is equivalence with the measurement value of Stethoscopy The error meets all the conditions in the YY0667 2008 Operatin...

Page 23: ...SYSTEMS CO LTD Spo2 Probe Spo2 10UC15 Spo2 Measurement Range 35 100 Measurement Accuracy 70 100 2 Pulse Measurement Range 30 250bpm Manufacturer CONTEC MEDICAL SYSTEMS CO LTD SOUTHEASTERN MEDICAL SUP...