If ambient temperature status bStatus is ON the temperature sensor is experiencing a
fault. Wait for two cycles to complete to see if the issue is persistent. If the issue is
persistent, check the wiring of temperature sensor module with Red Lion and with the
sensor. If the fault cannot be diagnosed replace the 05-0793 DPM Power Supply PCB
with Temperature Sensor and two cables.
12.8 Pressure
From the SYSTEM OVERVIEW page, clicking on the PRESS box will take the user to
the PRESSURE STATUS page (Figure 62). This will allow operators to monitor the the
pressure reading in DPM Reader in kPa.