ICE1-*-G60L-V1D, ICE1-*-G60L-C1-V1D
Commissioning for EtherNet/IP
8-DI Profiles
16-DO Profiles
8-DO Profiles
8-DI/8-DO Profiles
Generic Profiles
Connection
Type of connec-
tion
Diagnosis Instance ID
Length
8 DI + DIA
Input only
Yes
Output: 193
0 byte
Input: 104
6 byte
8 DI
Input only
No
Output: 193
0 byte
Input: 105
2 byte
Table 5.5
Connection
Type of connec-
tion
Diagnosis Instance ID
Length
16 DO + DIA
Exclusive owner
Yes
Output: 100
2 byte
Input: 106
5 byte
16 DO
Exclusive owner
No
Output: 100
2 byte
Input: 107
1 byte
Table 5.6
Connection
Type of connec-
tion
Diagnosis Instance ID
Length
8 DO + DIA
Exclusive owner
Yes
Output: 103
1 byte
Input: 106
5 byte
8 DO
Exclusive owner
No
Output: 103
1 byte
Input: 107
1 byte
Table 5.7
Connection
Type of connec-
tion
Diagnosis Instance ID
Length
8 DI/8 DO + DIA
Exclusive owner
Yes
Output: 103
1 byte
Input: 104
6 byte
8 DI/8 DO
Exclusive owner
No
Output: 103
1 byte
Input: 105
2 byte
8 DI/8 DO + DIA
Input only
Yes
Output: 193
0 byte
Input: 104
6 byte
8 DI/8 DO
Input only
No
Output: 193
0 byte
Input: 105
2 byte
Table 5.8
Connection
Type of connec-
tion
Diagnosis Instance ID
Length
Generic 16 DI + DIA
Listen only
Yes
Output: 192
0 byte
Input: 101
7 byte