5.2.1
16DIO Modules, Connections and Assembly Objects
ICE1-16DIO-G60L-V1D
ICE1-16DIO-G60L-V1D: Ethernet IO module with 16 digital inputs/outputs (16DIO), freely con-
figurable
16-DI/DO Profiles
8-DI/DO Profiles
16-DI Profiles
Note
The possible profiles for the Ethernet IO module with configurable inputs/outputs are listed
below.
First for the ICE1-16DIO-G60L-V1D module and then for the ICE1-16DIO-G60L-C1-V1D
module with DCU function.
Connection
Type of connec-
tion
Diagnosis Instance ID
Length
16 DI/DO + DIA
Exclusive owner
Yes
Output: 100
2 byte
Input: 101
7 byte
16 DI/DO
Exclusive owner
No
Output: 100
2 byte
Input: 102
3 byte
16 DI/DO + DIA
Input only
Yes
Output: 193
0 byte
Input: 101
7 byte
16 DI/DO
Input only
No
Output: 193
0 byte
Input: 102
3 byte
Table 5.2
Connection
Type of connec-
tion
Diagnosis Instance ID
Length
8 DI/DO + DIA
Exclusive owner
Yes
Output: 103
1 byte
Input: 104
6 byte
8 DI/DO
Exclusive owner
No
Output: 103
1 byte
Input: 105
2 byte
8 DI/DO + DIA
Input only
Yes
Output: 193
0 byte
Input: 104
6 byte
8 DI/DO
Input only
No
Output: 193
0 byte
Input: 105
2 byte
Table 5.3
Connection
Type of connec-
tion
Diagnosis Instance ID
Length
16 DI + DIA
Input only
Yes
Output: 193
0 byte
Input: 101
7 byte
16 DI
Input only
No
Output: 193
0 byte
Input: 102
3 byte