IntelliFlo VS 3050 and VSF+SVRS Pump Setup
(Continued)
Assign custom speeds (RPM) IntelliFlo VS 3050 pump
Each Intelliflo VS 3050 pump can have a maximum of eight assigned circuits with eight preset pump
speeds (RPM). The speeds can be set from 400 RPM to 3450 RPM.
To set the IntelliFlo VS 3050 pump speed to an assigned circuit name:
1. From the main pump screen, press the left side button next to the selected IntelliFlo VS 3050
pump.
Note: An IntelliFlo VS 3050 pump can only be assigned as pump #1, #2, #3, or #4.
2. On the next screen, press the left side button next to ASSIGN CUSTOM SPEEDS.
3. From the next screen you can assign a circuit name and set the pump speed. To assign a circuit
name, press one of the left side buttons next to “NONE.” Press the PREV or NEXT lower button
to select a circuit name for the pump. The selected circuit name must also be assigned a circuit
function. For details about assigning a circuit function, see page 39. Press the corresponding RPM
button on the right side to set the speed. Use the DOWN and UP lower buttons to adjust the speed
from 400 RPM to 3450 RPM.
4. Press the lower
SAVE
button to save the circuit and speed setting. To set another circuit and pump
speed, press the button next to ASSIGN CUSTOM SPEEDS to access the circuit and speed setup
screen. If you need additional pump speed circuits, press the button next to NEXT PAGE to access
an additional four circuits, then repeat step 3.
5. When finished, press the
BACK
button to return to the Equipment screen.
MENU SETUP EQUIPMENT INTELLIFLO
Getting There
MENU/SETP/EQUIP/INTELLIFLO/ASSIGN
BACK
NEXT
AUX 5 1500 RPM
AUX 6 2350 RPM
NONE 1000 RPM
NEXT PAGE
AUX 4 750 RPM
SAVE
PREV
MENU/SETP/EQUIP/INTELLIFLO/ASSIGN
BACK
UP
AUX 5 1500 RPM
AUX 6 2350 RPM
NONE 1000 RPM
NEXT PAGE
AUX 4 750 RPM
SAVE
DOWN
Press this
button to
assign a
circuit name
Press this
button to
set the
pump
speed
Prev and Next buttons
(use to assign a circuit name)
Down and Up buttons
(use to adjust pump speed)
MENU/SETP/EQUIP/IFLO/SELECT
BACK
EXIT
IFLO VS 3050 #2 SPA
NEXT GROUP OF PUMPS
IFLO VF 3050 #1 POOL
IFLO VS 3050 #4 AUX 3
IFLO VSF+SVRS #3
MENU/SETP/EQUIP/INTELLIFLO
BACK
EXIT
PENTAIR IFLO VS 3050
IFLO VS 3050 #4
ASSIGN CUSTOM SPEEDS
INTELLIFLO STATUS
PRIMING PARAMETERS
SPA
Select the
IntelliFlo VS
3050 pump
Press this
button to
access the
custom speed
screen
Summary of Contents for INTELLITOUCH