Setting up an UltraTemp Heat Pump
UltraTemp heat pump screen (HEAT PUMP COM)
From the HEATPUMPCOM screen you can view the current heat pump operation status, and set the
unit to operate with for heating only, cooling only or both heating and cooling if the unit is reversible.
Connection from the Pentair UltraTemp heat pump to the IntelliTouch system is via an RS-485
communication cable to a COM PORT on the IntelliTouch Personality circuit board. See page 112
for UltraTemp to IntelliTouch COM port wiring information. The UltraTemp heatpump must be set to
default ADDRESS 1. One UltraTemp unit can be connected to an IntelliTouch system.
Operating UltraTemp
The UltraTemp heat pump is reversible, meaning it can heat or cool. When cooling is selected, an option
heat control is displayed in the HEAT screen below the pool heat settings labeled as POOL MAX.
This setting allows you to set the maximum heat temperature setting for the pool before the UltraTemp
cooling begins.
To access the UltraTemp heat pump communication screen:
1. From the
EQUIPMENT
screen, press the left side button next to
HEATPUMPCOM
.
MENU SETUP EQUIPMENT HEATPUMPCOM
Getting There
MENU / SETUP /EQUIP
BACK
EXIT
CHLORINATOR
PRIORITY
INTELLIFLO
SOLAR
2-SPEED PMP
PUMP DELAYS
SPA OPTIONS
DEGREES C/F
HEATPUMPCOM
INTELLICHEM
MENU/SETP/EQUIPT/HEATPUMPCOM
BACK
NEXT
HEATPUMPCOM PRESENT
YES
HEATPUMPCOM HEATING
YES
HEATPUMPCOM COOLING
YES
OPERATION NORMAL
HEATPUMPCOM unit present (Yes/No)
HEATPUMPCOM cooling (Yes/No)
View current heat pump status
HEATPUMPCOM heating (Yes/No)
Decrease temperature
for UltraTemp
heat pump
Increase temperature for
UltraTemp heat pump
UltraTemp heat settings