IntelliTouch
®
Control System User’s Guide
104
Problem: Indoor and Outdoor Control Panels work, but iS10 fails to operate.
Symptom
Possible Cause
Solution
iS10 Spa Side fails to oper-
ate equipment .
Spa Side Control is
Disabled from the
main control panel.
Using the indoor panel or a serviceman’s panel.
Press ‘MENU’ and ensure the selection reads
“SPA SIDE REMOTE ENABLED”. If it reads “SPA
SIDE REMOTE DISABLED” press the button
beside the option to toggle the selection.
Defective Wiring
Verify iS10 setup. Press ‘MENU/SETUP/AD-
VANCED/SPA, RF, & PHONE REMOTES’Select
‘CONFIGURE iS10’s . Ensure the iS10 in question
has the expected circuit assignments, and is not
assigned to unused circuits.
Incorrect configu-
ration or circuit to
switch assignment.
Verify iS10 setup. Press ‘MENU/SETUP/AD-
VANCED/SPA, RF, & PHONE REMOTES’Select
‘CONFIGURE iS10’s’ Ensure the iS10 in question
has the expected circuit assignments, and is not
assigned to unused circuits.
IS10 is not correctly
enabled
See page 80 to manually enable the iS10.
Defective iS10
Replace defective iS10. Contact Technnical Sup-
port.