8.4.4 PAGING UNITS
Setting the volume of the broadcasting stations
Panel. for. setting. the. volume. of. the. microphone. stations. for. broadcasting.
announcements.and.viewing.the.setting.of.the.chime.
•.UNIT.VOLUME:
This.control.sets.the.general.volume.of.broadcasting.microphone.stations.of.the.
PMB106-G. and. PMB112-G. ranges. output. from. the. PA8506-V. unit. to. which. the.
stations.are.connected.by.means.of.the.“PAGING.UNITS”.socket.
8.4.5 CHIME
Management of the warning signal (chime)
Panel.for.setting.the.chime.that.is.produced.on.activating.a.
voice
.source.
•...
Attivazione del tono di Chime
:.
Press.keys.1,.2,.3.and.4.then.release.them.to.set.the.chimes.for.the.various.different.
sources:
1-.MIC1:. Input.IN.1.programmed.to.activate.the.announcement.via.the.Precedence.
contact.(see.point.8.4.1)..
2-.MIC2:. Input.IN.2.programmed.to.activate.the.announcement.via.the.Precedence.or.
VOX.contacts.(see.point.8.4.2).
3-.UNIT:. Microphone.stations.of.the.PMB106-G.and.PMB112-G.ranges.connected.to.
the.“Paging.Unit”.socket.and.Emergency.Units.PMB132-V.and.PMB132/12-V.
for.broadcast.announcements.connected.to.the.“Emergency.Unit”.socket.
4-VOX:.. Input.IN.3.programmed.to.activate.the.announcement.via.the.VOX.function.
(see.point.8.4.3).
The.label.shows.the.setting.that.has.been.selected:
. .
ON=Chime.active,.OFF=Chime.de-activated)
•...
Adjustment of the volume of the Chime tone:
Hold.key.5.(VOL).down.and.adjust.the.volume.by.turning.the.+/-.knob.within.the.range.
-30.dB/0.dB;.the.volume.is.common.to.all.four.inputs.and.is.separate.from.the.volume.
adjustment.assigned.to.the.sources.
•...
Loading the Chime tone from an external storage device:
It. is. possible. to. replace. the. warning. signal. with. another. available. in. the. USB. flash.
memory.device..Plug.the.flash.memory.device.into.the.USB.EXT..front.panel.socket,.
press.key.6.(FOLDER),.use..the.+/-.knob.to.choose.a.folder.from.the.Directory.Selection.
screen,..then.press.OK.to.confirm.
The.display.will.show.the.name.and.the.number.of.the.file.chosen.from.among.those.
contained.in.the.folder..Browse.through.the.contents.with.the.+/-.knob.and.press.OK.to.
copy.the.file.with.the.new.chime.to.the.memory.resident.in.the.PA8506-V.system.
•.EMG.UNITS.VOL.:.
This.control.sets.the.general.volume.of.the.emergency.units.of.the.PMB132-V.and.PMB132/12-V.ranges.solely.for.broadcast.announcements.
output.from.the.PA8506-V.unit.to.which.the.units.are.connected.via.the.“EMERGENCY.UNITS”.socket..Press.key.2.(VOL).and.hold.it.down.and.
turn.the.+/-.knob.to.adjust.the.volume.of.the.line.within.a.range.from.-30dB.to.0dB.
•.REMOTE.LINK:
In.a.12-zone.system,.this.control.adjusts.the.general.volume.of.the.microphone.stations.of.the.PMB106-G.and.PMB112-G.ranges.and.of.the.
emergency.units.of.the.PMB132-V.and.PMB132/12-V.ranges.for.broadcast.announcements.received.from.the.remote.PA8506-V.unit.connected.
to.the.local.PA8506-V.unit.via.the.“REMOTE.LINK”.socket..Hold.down.key.3.(VOL).and.turn.the.+/-.knob.to.adjust.the.volume.of.the.line.
•.CHIME:
This.control.shows.the.setting.of.the.chime.(ON/OFF).for.announcements.broadcast.by.stations.of.the.PMB106-G.and.PMB112-G.ranges.and.by.
emergency.units.of.the.PMB132-V.and.PMB132/12-V.ranges..For.the.settings,.see.point.8.4.5.illustrating.the.CHIME.panel.
---
To.set.the.priority.and.the.paging.zones.of.each.unit,.consult.the.appropriate.instruction.manual.
---
The.RESET,.ALERT,.EVAC,.MENU,.OK.keys.and.keys.from.2.to.6.are.not.operational..Press.ESC.to.return.to.the.AUDIO.SETTING.menu.
The.previous.chime.file.will.be.overwritten.and.it.will.not.be.possible.to.restore.it.
See.the.figure.opposite.for.further.details.
The.RESET,.ALERT,.EVAC,.MENU.and.OK.keys.are.not.operational.
Press.ESC.to.return.to.the.AUDIO.SETTING.menu..
requisiti del file audio per il tono di Chime
.
•.Formato:.*.WAV
•.Risoluzione:.16.bit./.mono
•.Frequenza.di.campionamento:.48.kHz