34
EVO Installation Guide
4.4.4 Instant Zones
SECTION
[0400]: F
IRST
DIGIT
= 4
S
ECTIONS
[0101]
TO
[0196]: F
IRST
DIGIT
= 4
When an armed Instant zone opens, the control panel immediately generates an alarm.
4.4.5 24Hr Buzzer Zones
SECTION
[0400]: F
IRST
DIGIT
= 5
S
ECTIONS
[0101]
TO
[0196]: F
IRST
DIGIT
= 5
Whenever a 24Hr Buzzer zone opens, the control panel activates the keypad buzzer to indicate that the zone
was breached. The control panel will report the alarm, but will not enable the bell/siren output. Enter any valid
access code on the keypad to stop the buzzer.
The keypads must be assigned to the same partition as the 24Hr Buzzer zone or the buzzer will not
activate. UL Note: Not to be used for perimeter protection.
4.4.6 24Hr Burglary Zones
SECTION
[0400]: F
IRST
DIGIT
= 6
S
ECTIONS
[0101]
TO
[0196]: F
IRST
DIGIT
= 6
When a 24Hr Burglary zone opens, the control panel will immediately generate a burglary alarm.
4.4.7 24Hr Hold-up Zones
SECTION
[0400]: F
IRST
DIGIT
= 7
S
ECTIONS
[0101]
TO
[0196]: F
IRST
DIGIT
= 7
When a 24Hr Hold-up zone opens, the control panel will immediately generate an alarm.
The SIA FSK reporting format includes specific codes to identify the alarm as a Hold-up, Gas, Heat, Water, or Freeze Alarm.
4.4.8 24Hr Gas Zones*
SECTION
[0400]: F
IRST
DIGIT
= 8
S
ECTIONS
[0101]
TO
[0196]: F
IRST
DIGIT
= 8
When a 24Hr Gas zone opens, the control panel will immediately generate an alarm.
4.4.9 24Hr Heat Zones**
SECTION
[0400]: F
IRST
DIGIT
= 9
S
ECTIONS
[0101]
TO
[0196]: F
IRST
DIGIT
= 9
When a 24Hr Heat zone opens, the control panel will immediately generate an alarm.
** UL Note:
UL Listed compatible devices must be used for UL systems. For UL Listed systems, this type of zone should be programmed as a pulsing Fire alarm.
4.4.10 24Hr Water Zones*
SECTION
[0400]: F
IRST
DIGIT
= A
S
ECTIONS
[0101]
TO
[0196]: F
IRST
DIGIT
= A
When a 24Hr Water zone opens, the control panel will immediately generate an alarm.
4.4.11 24Hr Freeze Zones*
SECTION
[0400]: F
IRST
DIGIT
= B
S
ECTIONS
[0101]
TO
[0196]: F
IRST
DIGIT
= B
When a 24Hr Freeze zone opens, the control panel will immediately generate an alarm.
* UL Note:
UL Listed compatible devices must be used for UL systems. For UL Listed systems, this type of zone must be programmed as a silent auxiliary alarm.
4.4.12 Delayed 24Hr Fire Zone
(Not to be used with UL Listed systems)
SECTION
[0400]: F
IRST
DIGIT
= C
S
ECTIONS
[0101]
TO
[0196]: F
IRST
DIGIT
= C
The Delayed 24Hr Fire Zone definition from
Figure 14
on page 38 is used in homes where a smoke detector
often generates false alarms. A zone programmed as Fire becomes normally open and requires an EOL resistor.
Summary of Contents for Digiplex EVO192
Page 1: ...Fire and Burglary Alarm System EVO192 Installation Guide...
Page 10: ...10 EVO Installation Guide...
Page 65: ...EVO Installation Guide 65 Event Reporting 10...
Page 125: ...EVO Installation Guide 125 Appendix F EVO192 CP 01 Implications as of June 13th 2014...
Page 136: ...136 EVO Installation Guide Notes...
Page 137: ...EVO Installation Guide 137...
Page 138: ...138 EVO Installation Guide...
Page 139: ...EVO Installation Guide 139...
Page 140: ...140 EVO Installation Guide Printed in Canada 10 2007 paradox com...
Page 147: ...paradox com EVO192 EI04...