1.1 EVO192 – Residential Fire and Burglar Alarm and Commercial Burglar Alarm System
1.1.1 System Description
The EVO192 is a Residential Fire and Burglar Alarm and Commercial Burglar Alarm System consisting of
Controller EVO192, 8-Zone Expansion Module ZX8, HUB Module HUB2, IP Communication Module IP150,
Hardwired Keypads K641and TM50, Wireless Expansion Module RTX3.
The EVO192 Controller consists of 8 on-board zone inputs (16 with zone doubling) that is expandable to a
maximum of 192 zones via the 4-wire combus. The EVO Controller features up to 999 users, 8 partitions, 32
doors and can support up to 254 modules in any combination.
The EVO192 system provides the highest level of protection for use in Mercantile, high-security military and
government sites, luxurious residential homes and any place where maximum security is essential. These
systems are designed to be easy to use, and the modular concept of these systems provides installers with
labor-saving features that make expanding, installing and servicing these systems quick and convenient.
The EVO192 Controller is connected to Detection Devices protecting different zones of the premises. These
Zones can also be divided into different Partitions.
Keypads (K641 and TM50) are connected to the Control Panel in order to command, control and program the
system. In addition to the Bells connected to the Control Panel, the keypads are also used for annunciation and
indication of the information of the system such as events, alerts, warnings.
When required, expand the number of zones in the EVO192 system by adding ZX8 and RTX3 expansion
modules
1
anywhere and in any combination on the 4-wire combus. Modules are connected to the combus at
the most convenient location and then their zone inputs are assigned to the desired zone and partition. Also,
only a module’s used inputs are assigned to zones in the system.
EVO192 also supports 32 virtual zones in addition to its security zones. Virtual zones can be used to automate
PGM (Programmable Output) activations without occupying a security zone and without affecting the system’s
security functions. The EVO192 system is a logical solution to every installer’s security.
1.2 Features of EVO192 Controller
• Digital combus:
• Provides constant power, supervision and two-way communication between the control panel and all its
modules
• Supports up to 127 modules
• Connect modules up to 914m (3000ft) from the panel
2
• Sabotage-proof technology without additional wiring
• 8 on-board zones (16 w/ zone doubling) expandable to 192 zones via 4-wire combus
• Automatic Daylight Saving Time feature
• 2 on-board solid-state relays PGM outputs (+ 3 optional), negative or positive triggering
• PGM1 can be used as a 2-wire smoke input
3
• Built-in-real-time clock backup battery
• 1 supervised bell output, auxiliary output and telephone line
• Push button software reset (reset to default values and restart)
• Push button to activate or deactivate the Auxiliary output
1 – Connection of non ETL/UL listed component will void the ETL listing
2- Connect according to the wiring requirements described in the Wiring Diagram
Summary of Contents for Digiplex EVO192
Page 1: ...Fire and Burglary Alarm System EVO192 Installation Guide...
Page 10: ...10 EVO Installation Guide...
Page 65: ...EVO Installation Guide 65 Event Reporting 10...
Page 125: ...EVO Installation Guide 125 Appendix F EVO192 CP 01 Implications as of June 13th 2014...
Page 136: ...136 EVO Installation Guide Notes...
Page 137: ...EVO Installation Guide 137...
Page 138: ...138 EVO Installation Guide...
Page 139: ...EVO Installation Guide 139...
Page 140: ...140 EVO Installation Guide Printed in Canada 10 2007 paradox com...
Page 147: ...paradox com EVO192 EI04...