11.5 Switch To Pulse
S
ECTION
[3036]: O
PTION
[7]
(default =
disabled
) When
is enabled, the control panel switches from tone dialing to pulse dialing on the fifth
attempt to report events to the monitoring station. The control panel continues to use pulse dialing until it
establishes communication. When the control panel switches to another monitoring station telephone
number, it returns to tone dialing and switches back to pulse dialing on the fifth attempt.
11.6 Bell On Communication Fail
S
ECTION
[3036]: O
PTION
[8]
(default =
disabled
) When enabled and the control panel fails to communicate with the monitoring station
when the partition is armed, the control panel can enable the BELL output.
11.7 Keypad Beep on Successful Arm or Disarm Report
S
ECTION
[3037]: O
PTION
[5]
(default =
disabled
) When enabled and a user arms or disarms a partition, the keypad emits a beep tone to
confirm that the monitoring station received the arming or disarming report code.
11.8 Dial Tone Delay
S
ECTION
[3037]: O
PTION
[7]
(default =
disabled
)
If more time is required, insert a 4-second pause into the desired telephone number sequence (see
section
10.4)
.
11.9 Call Waiting Cancel
1.
Section 4.5 requires a programmable option for call waiting cancel shall be required on communicators
that use media (e.g. PSTN) where call-waiting may be provisioned.
The programming for this feature must be added to the Programming Guide.
The installer needs to verify the code in the premises area for the telephone network that disables the call
waiting feature, then add it to the monitoring station number.
For example:
Receiving center phone number: 999-999-999
Call waiting cancelation code: *70
Phone number to program: *70P999999999
) Instructions that an automatic telephone dialer or similar device shall not be set or programmed to place a call
to a police station number that has not been specifically assigned by that police station for such service. The
instructions may be incorporated on the inside of the product, on a separate sheet, or as part of a manual. If not
included directly on the product, the instructions or manual shall be referenced in the marking information on
the product. .
Note:
Do NOT program this system or any of its modules to automatically place a call to a police station
number that has not been specifically assigned by that police station for such a service.
[7]
ON
If no dial tone is present, dialer hangs up after 32 secs.
[7]
OFF
If no dial tone is present, force dials after 3 secs.
Summary of Contents for Digiplex EVO192
Page 1: ...Fire and Burglary Alarm System EVO192 Installation Guide...
Page 10: ...10 EVO Installation Guide...
Page 65: ...EVO Installation Guide 65 Event Reporting 10...
Page 125: ...EVO Installation Guide 125 Appendix F EVO192 CP 01 Implications as of June 13th 2014...
Page 136: ...136 EVO Installation Guide Notes...
Page 137: ...EVO Installation Guide 137...
Page 138: ...138 EVO Installation Guide...
Page 139: ...EVO Installation Guide 139...
Page 140: ...140 EVO Installation Guide Printed in Canada 10 2007 paradox com...
Page 147: ...paradox com EVO192 EI04...