C.0.63 Confidential Mode Timer
Section
[012]
Section
[012]
determines the amount of time without action before the keypad enters Confidential Mode. The
Confidential Mode Timer can be set from 005 seconds to 255 seconds.
Default: 120 seconds
C.0.64 Muting
Section
[009]
Option
[3]
Option
[3]
OFF = Audible sounds (default).
Option
[3]
ON = Mute.
C.0.65 Beep on Exit Delay
Section
[009]
Option
[4]
Option
[4]
OFF = Exit Delay beep disabled.
Option
[4]
ON = Exit Delay beep enabled (default).
C.0.66 Chime on Zone Closure
Section
[009]
Option
[5]
Option
[5]
OFF = Chime on Zone Closure disabled (default).
Option
[5]
ON = Chime on Zone Closure enabled.
C.0.67 Beep on Trouble
Section
[010]
Options
[1]
To
[4]
System Troubles / Clock Loss
Option
[1]
OFF = Disabled (default).
Option
[1]
ON = Enabled.
Communicator Troubles
Option
[2]
OFF = Disabled (default).
Option
[2]
ON = Enabled.
Module / Communication Bus Troubles
Option
[3]
OFF = Disabled (default).
Option
[3]
ON = Enabled.
Zone Troubles
Option
[4]
OFF = Disabled (default).
Option
[4]
ON = Enabled.
C.0.68 Keypad Anti-tamper Enable
Section
[011]
Option
[5]
Option
[5]
OFF = Keypad's anti-tamper is disabled (default).
Option
[5]
ON = Keypad's anti-tamper is enabled.
Summary of Contents for Digiplex EVO192
Page 1: ...Fire and Burglary Alarm System EVO192 Installation Guide...
Page 10: ...10 EVO Installation Guide...
Page 65: ...EVO Installation Guide 65 Event Reporting 10...
Page 125: ...EVO Installation Guide 125 Appendix F EVO192 CP 01 Implications as of June 13th 2014...
Page 136: ...136 EVO Installation Guide Notes...
Page 137: ...EVO Installation Guide 137...
Page 138: ...138 EVO Installation Guide...
Page 139: ...EVO Installation Guide 139...
Page 140: ...140 EVO Installation Guide Printed in Canada 10 2007 paradox com...
Page 147: ...paradox com EVO192 EI04...