108
EVO Installation Guide
K641R Access Control Connection
Figure 23: : Typical Access Control Installation
Figure 24: : Access Control Overview
Figure 25: : Access Control Connections
1 = Request for Exit (REX) device (Paradoor)
2 = Door contact
3 = K641R LCD Keypad Module
4 = Locking device
5 = Control panel (EVO)
5
4
3
1
2
Door
Contact
(Z1)
Locking
Device
(PGM)
REX device (Z2)
K641R
Combus
To EVO control
panel
K641R
K641R
Fused external
power supply
(recommended)
Door Lock
IN4007
Diode
K641R
Paradoor (460)
Request to Exit device.
Must be connected to
Z
2
terminal.
If a door contact is not being used, install a jumper or a 1k
W
resistor across the
BLK
and
Z
1 terminals depending on the control panel’s EOL definition.
If the REX (Request for Exit) device is not being used, place a jumper across
the
BLK
and
Z
2 terminals.
Door Contact
Must be connected
to
Z
1
terminal.
* Follows control panel’s EOL definition.
No EOL
required
for
Z
2
.
Summary of Contents for Digiplex EVO192
Page 1: ...Fire and Burglary Alarm System EVO192 Installation Guide...
Page 10: ...10 EVO Installation Guide...
Page 65: ...EVO Installation Guide 65 Event Reporting 10...
Page 125: ...EVO Installation Guide 125 Appendix F EVO192 CP 01 Implications as of June 13th 2014...
Page 136: ...136 EVO Installation Guide Notes...
Page 137: ...EVO Installation Guide 137...
Page 138: ...138 EVO Installation Guide...
Page 139: ...EVO Installation Guide 139...
Page 140: ...140 EVO Installation Guide Printed in Canada 10 2007 paradox com...
Page 147: ...paradox com EVO192 EI04...