118
EVO Installation Guide
You can program the keypad to display up to a total of 48. Sections
[101]
to
[196]
correspond to zones 1 to 96
respectively. These zones are displayed on LED numbers 1 to 48 and are assigned values 001 to 048.
Do not assign more than one LED number to a zone. For example, you cannot assign LED number 33 to
zones 21 and 28. The rejection beep will remind you that a selected LED number is already assigned to
another section.
Every time the
[
CLEAR
]
key is pressed it will revert to the preceding step, unless entering in data in which
case it will erase the current entry.
C.0.60 Section Reset
Section
[040]
This section resets zone display sections
[101]
to
[196]
to default settings. Enter
[040]
to perform the reset.
C.0.61 Confidential Mode
Section
[009]
Option
[1]
In Confidential Mode all LEDs will turn off until either a button is pressed or an access code is entered.
Option
[1]
OFF = Disabled (default).
Option
[1]
ON = Enabled.
C.0.62 Exit Confidential Mode
Section
[009]
Option
[2]
Option
[2]
ON = Exit Confidential Mode by entering an access code.
Option
[2]
OFF = Exit Confidential Mode by pressing a button (default).
Option
[2]
must be set to ON on UL listed systems.
Option
[2]
will only work if option
[1]
is enabled.
Summary of Contents for Digiplex EVO192
Page 1: ...Fire and Burglary Alarm System EVO192 Installation Guide...
Page 10: ...10 EVO Installation Guide...
Page 65: ...EVO Installation Guide 65 Event Reporting 10...
Page 125: ...EVO Installation Guide 125 Appendix F EVO192 CP 01 Implications as of June 13th 2014...
Page 136: ...136 EVO Installation Guide Notes...
Page 137: ...EVO Installation Guide 137...
Page 138: ...138 EVO Installation Guide...
Page 139: ...EVO Installation Guide 139...
Page 140: ...140 EVO Installation Guide Printed in Canada 10 2007 paradox com...
Page 147: ...paradox com EVO192 EI04...