EVO Installation Guide
31
Zone Programming
4
Enter Section [0400],
then enter the
Enter the zone’s 8-
digit serial and 3-digit
input number (The
input number is not
Enter the zone’s
parameters
Enter the zone’s
report codes
Enter the zone’s label
Press [ENTER] to save
and go to the next
Pressing [CLEAR]
twice will exit the
zone programming
P
[ENTER]
Zone Definition
Partition
Zone Option
_____
_____
1 2 3 4 5 6 7 8
0 - Disabled
(default)
1
- Entry Delay 1
2
- Entry Delay 2
3
- Follow
4
- Instant
5
- 24Hr Buzzer
6
- 24Hr Burglary
7
- 24Hr Hold-up
8
- 24Hr Gas
9
- 24Hr Heat
A
- 24Hr Water
B
- 24Hr Freeze
C
- Delayed 24Hr Fire
D
- Standard 24Hr
Fire
E
- Stay Delay 1
F
- Stay Delay 2
1 - Assigned to Partition 1
(default)
2
- Assigned to Partition 2
3
- Assigned to Partition 3
4
- Assigned to Partition 4
5
- Assigned to Partition 5
6
- Assigned to Partition 6
7
- Assigned to Partition 7
8
- Assigned to Partition 8
[1]
Auto Zone Shutdown Enabled
[2] Bypass Enabled
(default)
[3]
Stay Zone
[4]
Force Zone
[5]
[6]
Zone Alarm Type
off
off
Steady Alarm
off
on
Pulsed Alarm
on
off
Silent Alarm
on
on
Report Only
[7]
Intellizone
[8]
Delay before Transmission
.
Ademco slow, Silent Knight fast, SESCOA, Ademco express or
Pager formats:
Key-in desired 2-digit hex values from 00 to FF.
Ademco format:
Use section
[4032]
to program a set of default Ademco report
codes from the
Auto Report Code Programming
on page 77.
Then to program the remaining report codes or to change some
Alarm Report Code
Alarm Restore
Report Code
Tamper Report Code
Tamper Restore
Report Code
__ / __
__ / __
__ / __
__ / __
In any Zone Programming option, pressing [ACC] will save
the data and go to the next zone on the same option
Input
2
Hardwired
Device B
Control Panel
SN#:020000A2
APR3-ZX8 Module
SN#: 34000041
Input 5
Detector A
SN#: 21000033
C
OMMUNICATION
N
ETWORK
Input Terminals
1 2 3 4 5 6 7 8
Detector A:
Hardwired Device A:
Hardwired Device B:
Hardwired Device C:
Zone#
1 =
2 =
3 =
4 =
Section#
[0001]
[0002]
[0003]
[0004]
Serial#
21000033
1A000252
020000A2
34000041
Input#
N/A
N/A
002
005
Keypad
SN#: 1A000252
Keypad Zone
Hardwired
Device C
Hardwired
Device A
Input Terminals
1 2 3 4 5 6 7 8
Com
Summary of Contents for Digiplex EVO192
Page 1: ...Fire and Burglary Alarm System EVO192 Installation Guide...
Page 10: ...10 EVO Installation Guide...
Page 65: ...EVO Installation Guide 65 Event Reporting 10...
Page 125: ...EVO Installation Guide 125 Appendix F EVO192 CP 01 Implications as of June 13th 2014...
Page 136: ...136 EVO Installation Guide Notes...
Page 137: ...EVO Installation Guide 137...
Page 138: ...138 EVO Installation Guide...
Page 139: ...EVO Installation Guide 139...
Page 140: ...140 EVO Installation Guide Printed in Canada 10 2007 paradox com...
Page 147: ...paradox com EVO192 EI04...