EVO Installation Guide
63
9.5.1 Tamper Bypass Options
S
ECTION
[3034]: O
PTION
[7]
(default =
enabled
) When enabled in section
[3034]
, the control panel will ignore the zone’s bypass definition
and will follow the option set in
section 9.5
(page 62) if a tamper or wire fault occurs on a bypassed zone. When
disabled, Tamper Recognition follows the zone’s bypass definition. This means that the control panel will not
perform any action if a tamper or wire fault occurs on a bypassed zone.
9.6 Keypad Panic Options
(default =
disabled
) The control panel can generate an alarm (audible, fire or report only) by pressing the
keypad Panic key(s). Refer to the table below for the keypad Panic keys. In the section that corresponds to the
desired partition, enable or disable options
[1]
through
[6]
:
Report Only
The keypad emits a single confirmation beep and transmits the report code.
OFF OFF
Disabled (default):
Displays zone open on the keypads, but will not generate an alarm
or trouble.
Not permitted on UL systems.
OFF
ON
Generates Trouble Only (when armed or disarmed):
The control panel displays
Zone Fault
in the Trouble Display and
transmits the defined report code (see
section 10.2
on page 67).
ON
OFF
When disarmed: Generates Trouble Only
The control panel displays
Zone Fault
in the
Trouble Display and transmits the defined report
code (see
section 10.2
on page 67).
When armed: Follows Zone Alarm Type
The control panel follows the zone’s alarm type
(
section 4.6.5
on page 36).
ON
ON
When disarmed: Generates Audible Alarm
The control panel displays
Zone Fault
in the Trouble Display,
transmits the defined report code (see
section 10.2
on page 67),
and generates an audible alarm.
When armed: Follows Zone Alarm Type
The control panel follows the zone’s alarm type (
section 4.6.5
on
page 36).
Partition 1:
[3123]
Partition 3:
[3323]
Partition 5:
[3523]
Partition 7:
[3723]
Partition 2:
[3223]
Partition 4:
[3423]
Partition 6:
[3623]
Partition 8:
[3823]
Option
Feature
Press and Hold 2 Seconds:
[1]
Panic 1
*
LCD keypads:
Keys
[1]
and
[3]
simultaneously
Grafica keypads:
The
key
[2]
Panic 2
*
LCD keypads:
Keys
[4]
and
[6]
simultaneously
Grafica keypads:
The
key
[3]
Panic 3
LCD keypads:
Keys
[7]
and
[9]
simultaneously
Grafica keypads:
The
key
Option
Alarm Type
[4]
Panic 1:
*
ON
= Audible
OFF
= Report Only
[5]
Panic 2:
*
ON
= Audible
OFF
= Report Only
[6]
Panic 3:
ON
= Fire
OFF
= Report Only
Summary of Contents for Digiplex EVO192
Page 1: ...Fire and Burglary Alarm System EVO192 Installation Guide...
Page 10: ...10 EVO Installation Guide...
Page 65: ...EVO Installation Guide 65 Event Reporting 10...
Page 125: ...EVO Installation Guide 125 Appendix F EVO192 CP 01 Implications as of June 13th 2014...
Page 136: ...136 EVO Installation Guide Notes...
Page 137: ...EVO Installation Guide 137...
Page 138: ...138 EVO Installation Guide...
Page 139: ...EVO Installation Guide 139...
Page 140: ...140 EVO Installation Guide Printed in Canada 10 2007 paradox com...
Page 147: ...paradox com EVO192 EI04...