background image

      Ningbo Kingdun Electronic Industry Co.,Ltd.              

 

 

Page 1 of 10

 

 

Document 

No.

 

QSP0701-A-31095-

401

 

Version

 

A/1

 

Model No.

 

LM-109E

 

Date 

 

2016-6-15

 

Pages 

 

10

 

 
 
 
 
 
 
 
 
 

LM-109E SMOKE ALARM 

 
 
 
 
 
 

User manual 

 
 
 
 
 
 

 

Prepared by

Liu Xueyong 

 
 
Audit

Fang Yongda 

 
 
Approved by

Long Xinglin 

Summary of Contents for LM-109E

Page 1: ...ctronic Industry Co Ltd Page 1 of 10 Document No QSP0701 A 31095 401 Version A 1 Model No LM 109E Date 2016 6 15 Pages 10 LM 109E SMOKE ALARM User manual Prepared by Liu Xueyong Audit Fang Yongda Approved by Long Xinglin ...

Page 2: ...tection or key test LED red flashes and continuous alarm is given Low sensitivity detection silent mode LED red flashes about every 10 seconds no alarm sound automatically cancel low sensi tivity detection about 9 minutes later Alarm memory LED green flashed 3 times about every 43 seconds and stops 24 hours later The first time you press test mute button after alarm is made the detector will hint ...

Page 3: ... measures must be ensured Perform function test 1 per week clean every 3 months Smoke detectors must be taken out of service at the latest after 10 years and replaced with a new device Mounting locations Mounting locations for smoke detectors Bedrooms children s rooms and corridors must be equipped basic requirement with smoke detec tors Always on the ceiling 50 cm from the wall or beam If the roo...

Page 4: ... a height 0 2m the smoke detector must be installed on a beam or girder as centrally as possible in the room see Fig c In rooms with a floor area of 60m2 an additional smoke detector must be installed per 60m2 Planning examples For apartments and single family homes Example for use in a single family home ...

Page 5: ...s and arrangements are recommended for detector positioning a Linear corridor b Rectangular corridor c Detector arrangement in large corridors d Detector arrangement in large corridors with corners Constructional features If a room is divided in height by a podium or a gallery a smoke detector is required beneath these ...

Page 6: ...th pedestal shaped ceiling with a ceiling slope 20 Remarks smoke detectors can be attached on the position left 1 or on the position right 2 Notes for ceiling installation For ceiling with joists height h of the joist 0 20m and an area of the ceiling box 36m2 or 36m2 a Example for ceiling 36m2 b Example for ceiling box 36m2 c Example of ceiling with joist height h of the joist 0 2m In corridors wi...

Page 7: ...kwise Fix the mounting plate with the help of the enclosed mounting material to the ceiling or wall Check first whether the supplied mounting materials is suitable for the structural quality of the wall ceiling Insert the smoke detector in the mounting bracket and rotate the smoke detector anti clockwise direc tion until it audibly engages ...

Page 8: ...at the same time it means the detector is working properly At the same time the detector enters low sensitivity detecting state the red LED light flashes every 10 seconds approx About 9 minutes later it enters normal detecting state from low sensitivity detecting state automatically Or press the test mute button again and cancel low sensitivity detecting state Erratic or low sound coming from your...

Page 9: ...e smoke alarm device is running into the silence mode Smoke alarms devices are conceived to minimize nuisance alarms The smoke alarm will automatically reset after approximately 9 minutes if after this period particles of combustion are still present the alarm will sound again The alarm silencer silence mode can be repeatedly used until the air has been cleared of the conditioning causing the alar...

Page 10: ...d electronics devices may no more be given to the unsorted waste The symbol of the waste bin on wheels refers to the necessity of separate collection Please help with environmental protection and see to it that this device is given to the for this purpose designated systems of waste sorting if you do not use it any longer Trouble shooting PROBLEM ACTION SOLUTION Smoke alarm does not sound when tes...

Reviews: