152
4.4.6.
Horizontal Dark Lines
START
Is the printout in Service Mode 3
normal?
Yes
No
Replace the Toner Cartridge.
1. Clean the BTR with a soft, dry
cloth.
2. Replace the BTR.
No
Yes
Check the Scanner mechanism.
Is the Toner Cartridge operational?
No
Yes
Is the LSU normal?
No
Yes
Replace the LSU.
Is the HVPS normal?
1. Check all connectors and
voltages on the HVPS.
2. Check the Spring Connector
and voltage on the HVPS.
3. Replace the HVPS.
Yes
No
END
No
Yes
Clean or replace the rollers.
Paper Travel
P
Are there any foreign particles or
stains on the BTR?
Are the Fuser and Pressure Roller
surfaces clean?