185
418
RCV
C
Receiver transmitted PIN in response to PRI-Q
from transmitter. (Transmitting operator
requests voice contact)
Line quality is poor. (There are excessive
errors in received data)
FCB PCB or LCU PCB are defective.
420
RCV
B
T1 timer (35 sec.) elapsed without detecting 300
bps signal.
Incorrect type of incoming call.(non-facsimile
communication)
Transmitter is defective.
FCB PCB or LCU PCB is defective.
421
RCV
B
Busy Tone is detected after sending NSF Signal. Remote station disconnects the line.
Wrong number is dialed.
422
XMT
B
Content of NSF (or DIS) or NSC (or DTC) was
invalid.
There is an incompatibility.
427
G3 RCV
B
DCN received to NSF/CSI/DIS transmitted.
The interface is incompatible.
433
XMT
RCV
B, D
T.30 Protocol abnormal.
Defective remote station.
434
XMT or RCV
B
CD (response from Modem) did not turn OFF
within 180 sec. after receiver detected FLAG
signal.
Remote unit is defective.
FCB PCB or LCU PCB is defective.
436
G3 RX
C
DCN received after transmitting FTT.
Transmitter is defective or incompatible.
Line quality is poor.
456
RCV
B
Received relay transfer request or confidential
document to distribute to a end receiving station
or all confidential mailboxes are used.
457
RELAYXMT
CONF.XMT/
POLL
B
Remote unit does not have Relayed XMT or
Confidential Comm. capability.
459
RCV
C
Failed training in Phase C.
Line quality is poor. (Training signal is distorted
due to line noise)
FCB PCB or LCU PCB are defective.
490
RCV
C
Sum of error line exceeded the limit (Parameter
70) by 64 lines.
Line quality is poor.
FCB PCB or LCU PCB are defective.
494
RCV
C
Interval between two EOLs was more than 10
sec. when receiver received message data.
Transmitter is defective.
Line quality is poor. (EOL is damaged due to
line noise)
FCB PCB or LCU PCB are defective.
495
XMT/RCV
C
During reception, CD turned OFF or continued
ON for long time.
During communication, lost loop - current.
Line is disconnected.
Transmitter is defective.
FCB PCB or LCU PCB are defective.
496
XMT
C
CS of modem is not able to turn ON.
FCB PCB is defective.
501
XMT/
RCV(V.34)
B
Remote unit’s Modem is not compatible.
502
XMT/
RCV(V.34)
B, C, D
During reception, CD turned OFF or continued
ON for long time.
During communication, lost loop - current.
Line is disconnected.
Transmitter is defective.
FCB PCB or LCU PCB are defective.
503
XMT/
RCV(V.34)
B, C, D
CS of modem is not able to turn ON during
training.
FCB PCB is defective.
Line is disconnected.
504
RCV/V.34
(Polling)
B
Polling is rejected from the remote station.
No polling document is set.
505
XMT/V.34
(Polling)
B
Polling XMT is rejected.
No polling document is set.
540
XMT ECM
B
No response after transmitting 3rd CTC or DCN
received.
Incompatible interface.
541
XMT ECM
D
No response after transmitting 3rd EOR or
received DCN.
Line is faulty.
LCU PCB abnormal.
542
XMT ECM
D
No response to the 3rd RR transmitted or
received DCN.
Remote unit is abnormal.
543
XMT ECM
D
T5 timer (60 sec.) elapsed without MCF.
Remote unit is abnormal.
544
XMT ECM
D
Stopped Transmission after EOR Transmission. Line is faulty.
LCU PCB abnormal.
550
RCV ECM
C
Timer between frames in phase C has elapsed. Defective remote station.
554
RCV ECM
D
Transmitted ERR after receiving EOR.
Faulty line.
555
RCV ECM
D
Transmitted PIN after receiving EOR.
Faulty line and Operator Call requested by RX
side.
570
RCV
B
Password or machine code did not match during
remote diagnostic communication.
571
XMT
B
Remote unit did not have the remote diagnostic
function.
580
XMT
B
Sub-address transmission to a unit that has their
DIS bit 49 (NSF bit 155) OFF.
Sub-address transmission to a unit that has no
Sub-address function.
Information Codes
Code
Mode
Phase
Description of Problem
Cause
Summary of Contents for Panafax DX-2000
Page 2: ......
Page 27: ...27 9 1 Screw 19 10 Release two Latch Hooks 11 Remove the SNS Assembly 121 9 10 11 ...
Page 49: ...49 2 15 Screw Identification Template ...
Page 57: ...57 3 7 3 Option Cassette Circuit 555 748 728 744 928 953 730 731 731 952 944 930 931 931 ...
Page 58: ...58 3 7 4 LAN Control Circuit 522 CN50 1102 1104 1101 N C N C RD N C N C RD TD TD ...
Page 59: ...59 3 7 5 Page Description Language Printer Interface Kit ...