Errors and warnings
Code
notification
SNMP trap
notification
Action to be taken
W2140
s
s
The changer unit is operating.
)
Check the changer status by control panel or Web interface and
retry processing after the status changes to “Ready”.
W2150
s
s
The specified processing cannot be performed because of the
magazine eject mode set for taking out a disc specified by an
application.
)
Turn off the magazine eject mode on the application, and try
again.
W3000
±
±
Detected that the life of the drive system is nearly at its end.
)
Replacing the drive system or peripheral circuit is recommended.
W3010
±
±
The redundancy of writing has decreased owing to a drive system
fault or a media defect during RAID writing.
)
Check the log records to determine if there is a drive system or
magazine defect, and if yes, take proper action in accordance
with the error or warning code corresponding to the defect.
W3011
±
±
When reading RAID, the read redundancy is low due to a failure of
the drive system or media.
)
Check the log records to determine if there is a drive system or
magazine defect, and if yes, take proper action in accordance
with the error or warning code corresponding to the defect.
W3020
±
±
A fault has been detected in several of the drives of the drive
system. The redundancy at RAID writing or RAID reading
decreases. To recover the redundancy, repair the drives.
)
For information on the conditions that cause the warning, refer to
W3030
±
±
One or more drives or discs in the drive system have failed to
startup. Redundancy during RAID writing or RAID reading is
reduced. Repairs might be required for recovery.
)
For information on the conditions that cause the warning, refer to
W3040
±
±
Writing to the magazine is not possible because the magazine
management information area has run out.
)
Take a copy to another magazine.
W3050
s
s
The RAID level cannot be set from the control panel or the Web
interface because it has been set from an application.