background image

IBM System Storage TS7650 ProtecTIER Deduplication
Appliance

for ProtecTIER 3.1.8

Installation Roadmap Guide

GA32-0920-02

Summary of Contents for TS7650 PROTECTIER DEDUPLICATION APPLIANCE

Page 1: ...IBM System Storage TS7650 ProtecTIER Deduplication Appliance for ProtecTIER 3 1 8 Installation Roadmap Guide GA32 0920 02...

Page 2: ...ections of this publication This edition applies to the TS7650 Appliance with ProtecTIER version 3 1 8 installed and to all subsequent releases and modifications until otherwise indicated in new editi...

Page 3: ...ontroller and disk expansion modules 19 About the TSSC and related components 19 Chapter 3 Installing the TS7650 Appliance 21 Installation checklist 21 Installing the frame 24 Applying cable labels 26...

Page 4: ...install ProtecTIER Manager 172 Enabling the Windows High Contrast option 173 Using the Windows high contrast scheme with ProtecTIER Manager 175 Customizing the color palette 178 Notices 181 Trademarks...

Page 5: ...etwork connections for stand alone OpenStorage configuration Feature Code 3457 46 29 Clustered power connections 48 30 Clustered 1 Gb Ethernet switch connections for VTL configuration 51 31 Clustered...

Page 6: ...67 Color selection Swatches tab 178 68 Default color versus custom color 179 vi IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...

Page 7: ...ion Feature Code 3456 59 26 Clustered Fibre Channel connections for VTL installations 62 27 Clustered Host Fibre Channel labels 63 28 Clustered Fibre Channel connections for OpenStorage installations...

Page 8: ...viii IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...

Page 9: ...A sample danger notice follows DANGER An electrical outlet that is not correctly wired could place hazardous voltage on metal parts of the system or the devices that attach to the system It is the res...

Page 10: ...cedures C016 Caution Do not connect an IBM control unit directly to a public optical network The customer must use an additional connectivity device between an IBM control unit optical adapter that is...

Page 11: ...set should have the appropriate safety approvals for the country in which the equipment will be installed IBM power cords for a specific country or region are usually available only in that country o...

Page 12: ...xii IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...

Page 13: ...ntion This product is not intended to be connected directly or indirectly by any means whatsoever to interfaces of public telecommunications networks neither to be used in a Public Services Network Co...

Page 14: ...xiv IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...

Page 15: ...always install the heaviest devices in the bottom of the rack cabinet Always install servers and optional devices starting from the bottom of the rack cabinets v Rack mounted devices are not to be use...

Page 16: ...ide the correct power connection to a rack refer to the rating labels located on the equipment in the rack to determine the total power requirement of the supply circuit v For sliding modules Do not p...

Page 17: ...e that you choose can support the weight of the loaded rack cabinet Refer to the documentation that came with your rack cabinet for the weight of a loaded rack cabinet Verify that all door openings ar...

Page 18: ...xviii IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...

Page 19: ...e Card NIC support for OpenStorage on 3958 DD4 and 3958 AP1 3170 Feature Code 3457 v New Red Hat Linux version 5 6 Major changes in and additions to this document since the last edition are found in t...

Page 20: ...ice You can call 1 800 IBM SERV for help and service if you are in the U S or Canada You must choose the software or hardware option when calling for assistance Choose the software option if you are u...

Page 21: ...or IBM support engineers Assist On site provides a launch in context feature such that support engineers can start Assist On site from within the session of the third party support tool For restricted...

Page 22: ...enter v The translated publications for this product are included with the product These documents and product specification sheets are also available from the following website http www 947 ibm com s...

Page 23: ...cTIER Deduplication Gateway IBM part number 95P8315 v IBM System Storage TS7650 ProtecTIER Software Upgrade Guide IBM form number SC27 3643 v IBM System Storage ProtecTIER User s Guide for Enterprise...

Page 24: ...M TotalStorage DS4000 EXP810 Storage Expansion Unit Installation User s and Maintenance Guide WTI network switch publications Publications for the Western Telematic network power switch can be found o...

Page 25: ...tle and version Publication form number for example GC53 1196 03 Page table or illustration numbers that you are commenting on with a detailed description of any information that should be changed Abo...

Page 26: ...xxvi IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...

Page 27: ...her have ordered one with the appliance or have one already available for use at the installation site While it is possible to operate a TS7650 Appliance without a connected TSSC note that IBM does no...

Page 28: ...group includes the following disks IBM System Storage ProtecTIER Appliance Edition V3 1 8 DVD This disk contains the software for the appliance server that runs on the Red Hat Linux operating system i...

Page 29: ...e with the TS7650 Appliance v Configuring ProtecTIER RAS on the 3958 AP1 servers v Verifying RAS configuration and testing Call Home v Configuring ProtecTIER for use with the TS7650 Appliance v Instal...

Page 30: ...de TS7650G or TS7650 Installation Roadmap Guide Labeling Instructions Software Upgrade and Replication Enablement Guide User s Guide ts760779 Introduction and Planning Guide customer Figure 1 Document...

Page 31: ...t replication Introduction and Planning Guide customer Best Practices Guide Server A Server B TS7650G or TS7650 Installation Roadmap Guide Software Upgrade and Replication Enablement Guide Server B in...

Page 32: ...i Assist On site AOS is a web based tool that enables a remote support representative in IBM to view or control the management node desktop More information is located at the Tivoli AOS website http w...

Page 33: ...y The RID is created from the replication grid ID and the repository internal ID in the grid replication timeframe A scheduled period of time for replication to take place for all policies shelf A con...

Page 34: ...rksheets provided in the IBM System Storage TS7650 ProtecTIER Deduplication Appliance and TS7650G Deduplication Gateway Introduction and Planning Guide IBM form number GA32 0918 For convenience copies...

Page 35: ...stallation service process Install and secure the AP1 frame in the designated location at the customer site Label and connect external power Ethernet and Fibre Channel cables as necessary Connect the...

Page 36: ...TIER Specialists or LBS Representatives SSRs Install the Storage Manager from the ProtecTIER Manager CD Release the system to the customer Document and report installation results 10 IBM System Storag...

Page 37: ...ich includes a Feature Code 3708 4 8 TB Fibre Channel Disk Controller if it has firmware levels supported by RAS send problem reports to the customer through email Attention The ProtecTIER version 3 1...

Page 38: ...y 1u Empty 1u Empty 1u Empty 1u Empty 1u Empty 1u Empty 1u Empty 1u Empty 1u Empty 1u Empty 1u Empty 1u TSSC 1u Empty 1u Empty 1u Empty 1u Empty 1u Empty 1u Empty 1u ts760574 TSSC Network Switch KVM 1...

Page 39: ...hannel Disk Controllers v six Feature Code 3707 4 8 TB Fibre Channel Disk Expansion Units v one Feature Code 3437 Cluster Connection Kit This kit contains the following two 1 Gb gigabit Ethernet switc...

Page 40: ...et ports See Figure 5 on page 15 and Table 3 on page 15 ts760575 ProtecTIER Server 4U Disk Controller 3u 1 Gb Ethe rnet Switch 1u ProtecTIER Server 4U Disk Controller 3u Empty 1u Empty 1u ProtecTIER S...

Page 41: ...BA 8 QPI Slot 1 Not used 9 QPI Slot 2 Not used A1 Integrated Ethernet 1 port Eth4 A2 Integrated Ethernet 2 port Eth5 B SYS MGMT Ethernet port System management Ethernet port used by the IMM as a Web i...

Page 42: ...d one 1 Gb quad port Ethernet adapter v two dual port Qlogic Fibre Channel HBAs v two on board Ethernet ports See Figure 6 Figure 7 and Table 4 Table 4 3958 AP1 server rear view Slot assignments ports...

Page 43: ...rt 1 Eth0 Port 2 Eth1 Port 3 Eth2 Port 4 Eth3 6 Slot 6 Qlogic HBA 7 Slot 7 Qlogic HBA 8 QPI Slot 1 Not used 9 QPI Slot 2 Not used A1 Integrated Ethernet 1 port Eth12 Eth8 A2 Integrated Ethernet 2 port...

Page 44: ...LED Table 6 Operator information panel Callout Description 1 Information LED 2 System error LED 3 Locator button locator LED 4 Ethernet port activity LEDs 5 Power control button cover 6 Power control...

Page 45: ...TSSC and its related components keyboard video mouse KVM KVM switch and 16 port network switch are factory installed in the 3958 AP1 frame As a result the KVM switch provides input and video connectio...

Page 46: ...TSSC meets the compatibility requirements discussed in the IBM System Storage TS7650 ProtecTIER Deduplication Appliance and TS7650G Deduplication Gateway Introduction and Planning Guide IBM form numbe...

Page 47: ...d alone and clustered appliance configurations Table 8 Appliance installation checklist U Task Description Where to find information Section 1 Perform preinstallation verification h 1 1 If applicable...

Page 48: ...ting TSSC only Label and connect an Ethernet cable from the external port of the TSSC to the customer network This document KVM switch TSSC and customer network Ethernet connections Feature Code 3456...

Page 49: ...nspecting indicator and fault LEDs on page 70 h 5 7 Validate Ethernet link up indicators from the disk controller to the server This document Visually inspecting indicator and fault LEDs on page 70 Se...

Page 50: ...floor ensure that the hole cutout in the floor is located under the rear of the frame 2 Use the 43 mm wrench P N 31L8313 supplied with the TS7650 to make the following adjustments to the frame levelin...

Page 51: ...frames with round mounting holes from the frame as shown in Figure 12 d Remove the cable tie securing the free end of the cable management arm for Server A to the cable management support arm as show...

Page 52: ...However it is suggested that you double check all cables and labels for accuracy See Table 9 for information about how cables are labeled Note The same label set is used to cable both the Appliance a...

Page 53: ...op PDU Primary power supply S1 S2 etc Slot 1 slot 2 etc Same SC Total Storage System Console or TSSC Same SC KVM System console KVM assembly Same SC SW System console Ethernet switch Same VTL Virtual...

Page 54: ...TJ5 indicate which outlet the associated component plugs into on the Top PDU The letters BJ followed by a number for example BJ8 indicate which outlet the associated component plugs into on the Botto...

Page 55: ...red installation only 16 DD4A P1 Network power switch plug 1 Clustered installation only 17 DD4A P2 Network power switch plug 5 Clustered installations only 18 DD4B P1 Network power switch plug 2 Clus...

Page 56: ...EXPB2 3 Disk Expansion 3u Disk Expansion 3u Disk Controller 3u Empty 1u Empty 1u Empty 1u Empty 1u TSSC 1u TSSC Network Sw KVM 1u ProtecTIER Server 4u Disk Expansion 3u Disk Expansion 3u Disk Expansi...

Page 57: ...and customer network connections other than replication and OpenStorage customer host network connections the connections for an OpenStorage configuration are identical For replication connections for...

Page 58: ...tand alone appliance 1 Use either Figure 15 on page 31 or Figure 16 and Table 11 to verify the cable connections made in manufacturing 2 If the customer requests make the connection from the TSSC to t...

Page 59: ...ice To On Device Location 1 Slot 5 port 1 Server A Customer network Customer specified device 19 Slot 5 port 3 Server A Customer replication network Customer specified device 20 Port A2 Server A Custo...

Page 60: ...OpenStorage configuration Feature Code 3456 Callout From On Device To On Device Location 1 Port 1 slot 3 Server A Designated device Customer host network 2 Port 2 slot 3 Server A Designated device Cu...

Page 61: ...Port 3 slot 5 Server A Customer replication network Customer specified device 10 Port A2 Server A Customer replication network Customer specified device Procedure Notes v Cat 5e or higher cable is req...

Page 62: ...g to Figure 19 on page 35 and Table 14 on page 35 v For OpenStorage installations with Feature Code 3457 installed label and connect Ethernet cables according to Figure 20 on page 35 and Table 15 on p...

Page 63: ...ller B H1 H2 H2 H1 P2 P1 P1 P2 ts760910 EXPB 1 1 CNB 1 CNA 1 EXPA1 1 1 2 5 8 1 2 1 2 1 2 1 2 ProtecTIER Server A Customer Network DD4A P1 P2 1 2 3 4 6 7 5 8 9 A1 A2 B V S E2 E1 E4 E3 1 2 3 4 Figure 21...

Page 64: ...R232 1B 1A 2B 2A 2A 2B 1B R232 1A EXPA1 3 EXPA1 2 EXPA1 1 CNA 1 EXPB1 3 EXPB1 2 EXPB1 1 CNB 1 1 2 7 6 5 11 10 9 1 2 1 2 1 2 1 2 1 2 3 4 6 7 5 Customer Network DD4A P1 P2 E2 E4 A1 A2 B V S E1 E3 8 9 1...

Page 65: ...er A P1 P2 H1 H2 H2 H1 P2 P1 P R232 R232 P Disk Expansion 1B 1A 2A 2B R232 R232 2B 2A 2B 2A 2B 2A 1B 1A 1B 1A 1A 1B 1A 1B 1A 1B 2A 2B 2A 2B EXPA2 3 EXPA2 2 EXPA2 1 CNA 2 EXPA1 3 EXPA1 2 EXPA1 1 CNA 1...

Page 66: ...s attached 9 CNB 1 P1 Disk Array Disk Expansion B1 2 1B 10 EXPB1 1 1B Disk Array Disk Expansion B1 2 1A 11 CNB 1 P2 Disk Array Disk Expansion B1 3 1B 12 CNA 2 P2 Disk Array Disk Expansion A2 1 1B 13 E...

Page 67: ...er a public network does not require an additional connectivity device 2 Use the applicable illustration to verify the Fibre Channel connections made in manufacturing 3 Ensure that all cables are rout...

Page 68: ...EXPB 1 1 CNB 1 CNA 1 EXPA1 1 1 2 5 8 1 2 1 2 1 2 1 2 ProtecTIER Server A Customer Network DD4A P1 P2 1 2 3 4 6 7 5 8 9 A1 A2 B V S E2 E1 E4 E3 1 2 3 4 Figure 25 OpenStorage Fibre Channel cabling two...

Page 69: ...B R232 P Disk Expansion R232 1B 1A 2B 2A 2A 2B 1B R232 1A EXPA1 3 EXPA1 2 EXPA1 1 CNA 1 EXPB1 3 EXPB1 2 EXPB1 1 CNB 1 1 2 7 6 5 11 10 9 1 2 1 2 1 2 1 2 1 2 3 4 6 7 5 Customer Network DD4A P1 P2 E2 E4...

Page 70: ...P R232 R232 P Disk Expansion 1B 1A 2A 2B R232 R232 2B 2A 2B 2A 2B 2A 1B 1A 1B 1A 1A 1B 1A 1B 1A 1B 2A 2B 2A 2B EXPA2 3 EXPA2 2 EXPA2 1 CNA 2 EXPA1 3 EXPA1 2 EXPA1 1 CNA 1 EXPB2 3 EXPB2 2 EXPB2 1 CNB...

Page 71: ...hen only one expansion unit is attached 9 CNB 1 P1 Disk Array Disk Expansion B1 2 1B 10 EXPB1 1 1B Disk Array Disk Expansion B1 2 1A 11 CNB 1 P2 Disk Array Disk Expansion B1 3 1B 12 CNA 2 P2 Disk Arra...

Page 72: ...y that does not go over a public network does not require an additional connectivity device 2 Use the applicable illustration to verify the Fibre Channel connections made in manufacturing 3 Ensure tha...

Page 73: ...Power connections This task describes cabling the power connections for a clustered TS7650 Appliance Chapter 3 Installing the appliance 47...

Page 74: ...and orientation of the Network Power Switch in this diagram might not reflect the actual physical orientation of the switch in the frame Figure 29 Clustered power connections 48 IBM System Storage TS7...

Page 75: ...Stand alone installation only 13 Bottom PDU J8 Bottom PDU J8 pigtail Stand alone installation only 14 Top PDU J8 Network power switch main bus power bus A 15 Bottom PDU J8 Network power switch backup...

Page 76: ...r network for both VTL and OpenStorage with the TS7650 Appliance server in a clustered configuration 1 Gb Ethernet switch connections This task describes the 1 Gb Ethernet switch connections for the T...

Page 77: ...erver B 19 Slot 5 port 3 Server A Customer replication network Customer specified device 20 Port A2 Server A Customer replication network Customer specified device 26 Slot 5 port 3 Server B Customer r...

Page 78: ...to verify the Ethernet connections made in manufacturing 4 Make any necessary adjustments to cable placement or labeling then go to Ethernet connections on page 50 to complete the Ethernet cabling 1...

Page 79: ...omer replication network Customer specified device 17 Port 4 slot 3 Server B Customer replication network Customer specified device 18 Port 4 slot 4 Server B Customer replication network Customer spec...

Page 80: ...rt A2 Server A Customer replication network Customer specified device 17 Slot 5 port 3 Server B Customer replication network Customer specified device P1 P2 9 E3 E4 2 8 P1 P2 9 E3 E4 22 24 9 10 11 12...

Page 81: ...tions on page 50 to complete the Ethernet cabling KVM switch TSSC and customer network Ethernet connections Feature Code 3456 The tasks in this section describe the TSSC KVM and customer network Ether...

Page 82: ...4 P P 8 9 A1 A2 B V S E1 E2 E3 E4 V U3 U4 23 22 21 24 9 11 10 Customer Network ts760915 13 1 2 1 2 1 2 1 2 ProtecTIER Server B 1 2 3 4 5 6 7 1 2 3 4 P P 8 9 A1 A2 B V S E1 E2 E3 E4 14 12 25 Figure 33...

Page 83: ...SC KVM 22 Port 3 KVM Switch Video port SC Server Port U3 23 Port 1 KVM Switch Video port Server A Port E1 24 Port U1 KVM Switch Video Port SC KVM 25 Port 2 KVM Switch Video port Server B Port E1 1 2...

Page 84: ...e customer is enabling the data replication feature 2 If the customer requests make the connection from the TSSC to the customer specified device as shown 3 Perform one of the following v If the insta...

Page 85: ...device Customer host network 10 Slot 4 port 1 Server B Designated device Customer host network 11 Slot 4 port 2 Server B Designated device Customer host network 12 Slot 4 port 3 Server B Designated de...

Page 86: ...nstallation figures examples and procedures Note If the IP address of an SMTP server is provided during ProtecTIER RAS configuration the disk storage subsystems that communicate with RAS sends problem...

Page 87: ...1A 1B 1A 1B 2A 2B 2A 2B 1 2 1 2 1 2 1 2 1 2 3 4 6 7 5 Customer Network Customer Network EXPA2 3 EXPA2 2 EXPA2 1 CNA 2 EXPA1 3 EXPA1 2 EXPA1 1 CNA 1 EXPB2 3 EXPB2 2 EXPB2 1 CNB 2 DD4B DD4A EXPB1 3 EXPB...

Page 88: ...XPB1 2 1A 11 CNB 1 P2 EXPB1 3 1B 12 CNA 2 P2 EXPA2 1 1B 13 EXPA2 1 1A EXPA2 2 1B 14 CNA 2 P1 EXPA2 3 1B 15 CNB 2 P1 EXPB2 2 1B 16 EXPB2 1 1B EXPB2 2 1A 17 CNB 2 P2 EXPB2 3 1B 18 DD4B S6 1 CNA 2 H1 Use...

Page 89: ...gure 36 on page 61 Note The customer must use an additional connectivity device between the optical Fibre directly connected to RMSS optical adapters for example Fibre ESCON or FICON and an external p...

Page 90: ...configuration with OpenStorage configuration About this task Note The following figure shows Fibre Channel connections in a VTL installation however the relevant Fibre Channel connections to be made o...

Page 91: ...2A 2B 2A 2B 1 2 1 2 1 2 1 2 1 2 3 4 6 7 5 Customer Network Customer Network EXPA2 3 EXPA2 2 EXPA2 1 CNA 2 EXPA1 3 EXPA1 2 EXPA1 1 CNA 1 EXPB2 3 EXPB2 2 EXPB2 1 CNB 2 DD4B DD4A EXPB1 3 EXPB1 2 EXPB1 1...

Page 92: ...1B EXPB1 2 1A 11 CNB 1 P2 EXPB1 3 1B 12 CNA 2 P2 EXPA2 1 1B 13 EXPA2 1 1A EXPA2 2 1B 14 CNA 2 P1 EXPA2 3 1B 15 CNB 2 P1 EXPB2 2 1B 16 EXPB2 1 1B EXPB2 2 1A 17 CNB 2 P2 EXPB2 3 1B 18 DD4B S6 1 CNA 2 H1...

Page 93: ...Use Figure 38 on page 65 and Table 28 on page 66 to verify the Fibre Channel connections made in manufacturing 2 Connect the Fibre Channel cables to the customer host network according to Figure 39 a...

Page 94: ...nsion modules About this task For power on instructions refer to the IBM TotalStorage DS4000 EXP810 Storage Expansion Unit Installation User s and Maintenance Guide Important Precautions must be taken...

Page 95: ...wer but is not powered on The power control button will not become active for up to three minutes after the server has been connected to AC power The power supply fans are on while the server is conne...

Page 96: ...up Visually inspect the indicator and fault LEDs on all TS7650 Appliance appliance components v If all link up indicators and fault LEDs show normal operation close the front and rear doors of the fr...

Page 97: ...configuration so that the KVM switch GUI accurately reflects the unique system setup at the customer site Note Use the arrow keys to navigate among the options on the KVM GUI Procedure Perform the fol...

Page 98: ...rs are A through Z a through z 0 through 9 space and hyphen d Click OK The new name displays on the Names screen 2 Repeat Step 1 for all other devices attached to the KVM switch 3 When all devices hav...

Page 99: ...dio button is the only one selected and then click OK c Click OK KVM switch configuration is now complete 2 Press Esc to return to the Setup screen and then press Esc again to return to the Main scree...

Page 100: ...iewing KVM switch firmware version information This topic describes how to check the firmware version of the KVM switch Procedure Perform the following steps to view KVM switch firmware version inform...

Page 101: ...default destination results in an attempt to extract files to the CD ROM drive E instead of to a location on the hard disk drive which causes an error Establishing a connection between the TSSC and t...

Page 102: ...port to the TSSC Ethernet switch Note This cable is used to allow RAS configuration to reconfigure the IP address of the IMM port The two Ethernet cables are now connected to the TSSC Ethernet switch...

Page 103: ...hown in the login panel title If you are currently logged in to the TSSC Right click the TSSC blue desktop The IBM TS3000 System Console menu displays The microcode level in use on the TSSC is shown i...

Page 104: ...ed topics in IBM System Storage TS3000 System Console TSSC Maintenance Information for detailed instructions for backing up and restoring configuration data v Do not attempt to restore configuration s...

Page 105: ...ence continues each time the TSSC is powered on If the TSSC is unable to determine its machine type and model similar symptoms occur after software installation Note If a product with a machine type o...

Page 106: ...sections in the IBM System Storage TS3000 System Console TSSC Maintenance Information provided on the IBM System Storage TS7650 with ProtecTIER Publications CD v Do not select the Software Call Home...

Page 107: ...and Password fields 8 Click OK The Console Configuration application starts and the Console Configuration utility screen displays 9 Click Console Settings The Console Settings screen displays See Figu...

Page 108: ...Properties pane enter the customer supplied Host Name the unique name of the TSSC Domain Name DNS1 and DNS2 addresses and Default Gateway address Note If necessary scroll down to access the Default Ga...

Page 109: ...TP Server is off If necessary click Stop NTP server b In the Time fields enter the current UTC c Click Save Changes 17 Click Start NTP server The Console Time and Date screen displays again with the n...

Page 110: ...are returned to the TSSCs blue desktop 19 Go to Chapter 6 Enabling ProtecTIER RAS functions on page 85 Figure 49 Console Time and Date screen NTP server running 84 IBM System Storage TS7650 ProtecTIE...

Page 111: ...saster recovery information to assist the customer in restoration is available in the IBM System Storage ProtecTIER User s Guide for Enterprise Edition and Appliance Edition IBM form number GA32 0922...

Page 112: ...ved or in use by another TSSC managed device You can see the current frames being used by logging in directly to the TSSC The GUI can be accessed at the following address http tssc ip address 7080 TSS...

Page 113: ...Note The country code is the two digit IBM assigned country code used to order software or to acquire software support Do not confuse this country code with the three digit RETAIN country code v Simp...

Page 114: ...system view 8 Update ProtecTIER code E Exit Your choice b Type the numeral corresponding to ProtecTIER Configuration and press Enter The ProtecTIER Configuration menu displays ProtecTIER Service Menu...

Page 115: ...ding to Display services status and press Enter d Perform one of the following choices v If all services show a status of UP go to step 6 v If one or more services do not show a status of UP go to ste...

Page 116: ...orm the following steps to verify the complex systems attached to the TSSC 1 If not already logged in to the TSSC log in with the user ID service and password service 2 Right click the desktop and fro...

Page 117: ...x view definition 6 Configure TSSC 3958 AP1 frame definition Verify that each system in the 3958 AP1 frame is attached to the TSSC See Figure 51 a Select the heading for Complex View Note All 3958 AP1...

Page 118: ...a complex system c The 3958 AP1 systems associated with the IP range are added as a complex See Figure 53 on page 93 ts760206 Figure 52 TS3000 System Console Complex View window 92 IBM System Storage...

Page 119: ...column of the Attached Systems window If so the complex systems configuration was successful See Figure 54 on page 94 If it does not contact your next level of support ts760207 Figure 53 TS3000 Syste...

Page 120: ...able 33 Table 33 Determining when to run the battery calibration procedure Scenario If you are Perform this procedure on 1 installing a new stand alone TS7650 AP1 appliance in accordance with the IBM...

Page 121: ...hanging to Clustered Configuration Upgrade Installation Instructions Server B only 6 upgrading an existing stand alone TS7650G gateway to a cluster in accordance with the IBM System Storage TS7600 wit...

Page 122: ...0 mA Absolute state of charge 76 Max Error 25 Exit Code 0x00 2 Choose one of the following options v If a learn cycle is not active on the server you must initiate the battery calibration process Proc...

Page 123: ...e CCPF system v User Initiated Call Home Triggered from the TSSC GUI to collect a product engineering PE package Completion of this task is not strictly necessary for successful installation of the ap...

Page 124: ...and password enter service in both fields g Click Call Home Queue The Call Home Queue screen displays If the Call Home Queue is empty the call might have already been sent to the IBM Customer Configur...

Page 125: ...lation and configuration for which the SSR is responsible is now complete 4 Turn the system over to the trained ProtecTIER specialist or LBS representative for installation and configuration of Protec...

Page 126: ...100 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...

Page 127: ...y configured Note Throughout this chapter the terms server and node and target and destination are used interchangeably depending upon the task being performed Procedure To confirm the disk storage is...

Page 128: ...ance on page 27 Ethernet connections on page 50 or Fibre Channel connections on page 60 for additional information v TCP ports 3501 and 3503 used by ProtecTIER Manager are open in the firewall at the...

Page 129: ...on power it on now wait for the boot cycle to complete then go to step 2 2 Log in to the server a If a TSSC and its related components reside inside the AP1 frame use the KVM to access the servers 1 O...

Page 130: ...rvice Menu running on rasap1 1 ProtecTIER Configuration 2 Manage ProtecTIER services 3 Health Monitoring 4 Problem Alerting 5 Version Information 6 Generate a service report 7 Generate a system view 8...

Page 131: ...listed At each prompt type the new value and then press Enter Important Values set during manufacturing are displayed in brackets If you are enabling replication you must change all of the default va...

Page 132: ...Update the System s name 9 Validate configuration B Back E Exit Your choice c Type the numeral corresponding to Configure replication and press Enter The Configure Replication menu displays ProtecTIE...

Page 133: ...Enter The following status messages display Starting Cluster please wait Starting Cluster Done Cluster Started d When prompted type the new system name and press Enter Note The system name is a uniqu...

Page 134: ...6 IP Network configuration 7 Update Firmware 8 Update the System s name 9 Validate configuration B Back E Exit Your choice c Type the numeral corresponding to Configure replication and press Enter The...

Page 135: ...is entry Please provide the following information Target Network Address for example 10 11 194 0 starting network address Target Network Netmask for example 255 255 255 0 Local Gateway Address for exa...

Page 136: ...ite 1 and site 2 Actual values vary Depending on your replication configuration if more than one node is replicating to a single node the remote node Target Network Address might be the same network s...

Page 137: ...ay Address The gateway address for Server A at Site 2 1 eth2 2 eth5 Table 37 Site 2 Server B VTL worksheet Site 2 Server B ID Target Network Address Remote nodes starting network address Target Netmas...

Page 138: ...gateway address for Server A at Site 2 1 eth7 2 eth11 Table 41 Site 2 Server B OpenStorage Feature Code 3456 worksheet Site 2 Server B ID Target Network Address Remote nodes starting network address...

Page 139: ...th9 Table 45 Site 2 Server B OpenStorage Feature Code 3457 worksheet Site 2 Server B ID Target Network Address Remote nodes starting network address Target Netmask Remote nodes netmask Local Gateway A...

Page 140: ...ote Refer to the Best Practices Guide for IBM System Storage TS7600 ProtecTIER Deduplication Solutions IBM form number GA32 0924 for more detailed information about updating the application related IP...

Page 141: ...pe the numeral corresponding to Configure ProtecTIER s application IP interfaces and press Enter For OpenStorage installations with FC 3456 installed output similar to the following example displays I...

Page 142: ...o reassign and the virtual device to assign it to from the available virtual devices displayed Example for OpenStorage with Feature Code 3456 installed Interface L B Method IP Address Netmask Devices...

Page 143: ...ange the system date time and timezone and add timeservers to the system Attention If you use this procedure to change the date and time consider committing the changes and exiting the session once yo...

Page 144: ...me 2 Set Timezone 3 Set Timeserver s c Commit changes and exit q Exit without committing changes Please Choose 2 Type the numeral corresponding to Set date time and then press Enter to synchronize the...

Page 145: ...ezone manually 6 For example to set the local timezone for the United States type US and press Enter If you need a list of time zone codes from countries other than the United States see Appendix D Wo...

Page 146: ...lay a Please specify the timeserver s IP Address Enter the timeserver IP address For example type 192 168 10 15 and press Enter b Would you like to set a secondary timeserver yes no Type y and press E...

Page 147: ...opping Cluster Services Done Stopping NTPD Done Setting Time Zone Done Setting Timeserver Done Setting Date Time Done Starting NTPD Done Starting cluster Done Cluster Started Starting VTFD Done Starti...

Page 148: ...es For example Begin Procedure Verify storage and server installation System health state OK Disk Array Health State is OK Server Health State is OK Adapters Health State is OK Software Health State i...

Page 149: ...s to run the cluster validation test 1 If you are not already connected to Node A choose one of the following options as applicable v If you are using the KVM switch press the PrtSc key on the TSSC ke...

Page 150: ...he fence device Done Would you like to stop the VTFD service on both nodes yes no 5 Type yes and press Enter The following message is displayed Stopping VTFD locally 6 After VTFD is stopped and the te...

Page 151: ...ystem to the customer and refer the customer to the IBM System Storage ProtecTIER User s Guide for Enterprise Edition and Appliance Edition IBM form number GA32 0922 for information about managing and...

Page 152: ...126 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...

Page 153: ...nstalling ProtecTIER Manager on a workstation running Linux see Installing on a Linux workstation on page 131 The ProtecTIER Manager installation wizard and the ProtecTIER Manager application are full...

Page 154: ...anager V3 1 8 DVD The following message displays Installation may last a few moments Please be patient 6 When the ProtecTIER Manager installation wizard starts follow the on screen instructions to com...

Page 155: ...Windows workstation 1 Insert the IBM System Storage ProtecTIER Manager V3 1 8 DVD into the CD ROM drive of the designated ProtecTIER Manager workstation v If the ProtecTIER Manager installation wizard...

Page 156: ...Next The Choose Shortcut Folder screen opens 5 Select the destination location for the program icons ts760224 Figure 56 Choose Install Folder screen ts760199 Figure 57 Choose Shortcut Folder screen 13...

Page 157: ...remain at its manufactured naming convention DS_Cache_Subsystem or DiskArray xxx xxx for proper storage error reporting 10 Go to Adding a node on page 134 Installing on a Linux workstation This topic...

Page 158: ...Note In all commands below XX is 64 or 32 Type InstallLinuxXX bin and press Enter If the message Permission denied displays type the following two commands chmod x InstallLinuxXX bin and press Enter...

Page 159: ...en the installation finishes the Install Complete screen displays 10 Click Done The ProtecTIER Manager Wizard closes 11 When the command prompt returns to the Terminal window type Exit and then press...

Page 160: ...click the ProtecTIER Manager icon on the Linux desktop Note If you do not have the ProtecTIER Manager icon on your Linux desktop navigate to the directory where you installed ProtecTIER Manager the de...

Page 161: ...6 The installation and configuration processes are now complete Proceed to Chapter 9 What to do next on page 137 Chapter 8 Installing ProtecTIER Manager and Storage Manager 135...

Page 162: ...136 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...

Page 163: ...s complete Procedure Follow the standard IBM procedures for releasing the system to the customer and refer the customer to the IBM System Storage ProtecTIER User s Guide for Enterprise Edition and App...

Page 164: ...138 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...

Page 165: ...e two character code that must be used in order to reach your country by phone or fax from another country This is not the three digit RETAIN country code See Table 47 on page 141 Frame range number T...

Page 166: ...mber An alternate fax number that IBM service representatives can use to fax documents to the storage system administrator Include the area code and the country code if appropriate Administrator maili...

Page 167: ...blic cz Ireland ie New Caledonia French nc Sri Lanka lk Anguilla ai Denmark dk Israel il New Zealand nz Sudan sd Antarctica aq Djibouti dj Italy it Nicaragua ni Suriname sr Antigua and Barbuda ag Domi...

Page 168: ...n gb Marshall Islands mh Saint Helena sh Vanuatu vu Cambodia kh Greece gr Martinique French mq Saint Kitts Nevis Anguilla kn Vatican City State va Cameroon cm Greenland gl Mauritania mr Saint Lucia lc...

Page 169: ...0 Appliance servers with OpenStorage configurations Table 53 on page 147 shows the IP address network mask DNS and VLAN settings for the source and destination servers for replication This information...

Page 170: ...y default IP addresses for a stand alone OpenStorage configuration for a TS7650G 3958 DD4 or TS7650 Appliance Table 49 Factory default server IP addresses for a stand alone OpenStorage ProtecTIER serv...

Page 171: ...rk 1 10 0 0 51 Server A eth2 Replication network 1 192 168 20 1 Server A eth3 RAS 172 31 1 xx Server A eth4 Cluster network 2 10 0 0 51 Server A eth5 Replication network 2 192 168 21 1 Network Power S...

Page 172: ...168 154 1 Server A eth10 OpenStorage 192 168 155 1 Server A eth11 Replication network 2 192 168 21 1 Server A eth12 Cluster network 2 10 0 0 51 Server A eth13 Free Network Power Switch N A 10 0 0 50...

Page 173: ...nStorage systems provide a routing path from the IP address on eth7 site1 to the IP address of eth7 site2 and a routing path from the IP address on eth11 site1 to the IP address of eth11 site2 Source...

Page 174: ...at you are assigning to the TSSC for example medina xyz it Ethernet settings Complete the LAN Adapter Details section when the TSSC connects to your LAN Media speed Ethernet Check Autodetection or the...

Page 175: ...ateway for routing Gateway address Confirm and record the dotted decimal or symbolic name address of the gateway for example 8 127 155 254 or londongate TSSC IP addresses Table 55 TSSC IP addresses TS...

Page 176: ...up the second node If you reply Yes the code will set the IP range for node 2 at 5 octets higher than what is set for node 1 server A For example if server A is set for 172 31 1 10 then server B will...

Page 177: ...ending upon the equipment you have available perform the procedures that follow either by using a USB keyboard and graphics capable monitor the preferred method or by using the TSSC at microcode versi...

Page 178: ...the default of 254 For example 172 31 1 253 8 For the Netmask enter 255 255 255 0 9 Leave the Gateway field blank 10 Ensure that use of the static IP address is specified 11 Select Save the Network C...

Page 179: ...address 8 In the IP address field type 172 31 1 14 or 192 168 70 33 if the IMM is new and in the Subnet mask field type 255 255 255 0 9 Click OK and then click Close to exit the Local Area Connection...

Page 180: ...minutes is usually sufficient Do not select the No Timeout setting as this action prevents anyone else from logging in to the IMM until you have logged out b Click Continue See Figure 60 You are now l...

Page 181: ...session active until you can complete your task 10 minutes is usually sufficient Do not select the No Timeout setting as this action prevents anyone else from logging in to the IMM until you have log...

Page 182: ...ystem Console TSSC or your notebook is configured to block pop up windows temporarily disable this function Accept any Java versions that are displayed as well as any Windows security prompts displaye...

Page 183: ...er Palmer Station Anvers Island AQ Antarctica Mawson Mawson Station Holme Bay AQ Antarctica Davis Davis Station Vestfold Hills AQ Antarctica Casey Casey Station Bailey Peninsula AQ Antarctica Vostok V...

Page 184: ...urope Mariehamn AZ Asia Baku BA Europe Sarajevo BB America Barbados BD Asia Dhaka BE Europe Brussels BF Africa Ouagadougou BG Europe Sofia BH Asia Bahrain BI Africa Bujumbura BJ Africa Porto Novo BL A...

Page 185: ...navut most locations CA America Pangnirtung Eastern Time Pangnirtung Nunavut CA America Resolute Eastern Time Resolute Nunavut CA America Atikokan Eastern Standard Time Atikokan Ontario and Southampto...

Page 186: ...i most of Tibet Xinjiang CN Asia Kashgar west Tibet Xinjiang CO America Bogota CR America Costa_Rica CU America Havana CV Atlantic Cape_Verde CX Indian Christmas CY Asia Nicosia CZ Europe Prague DE Eu...

Page 187: ...Scoresbysund Ittoqqortoormiit GL America Thule Thule Pituffik GM Africa Banjul GN Africa Conakry GP America Guadeloupe GQ Africa Malabo GR Europe Athens GS Atlantic South_Georgia GT America Guatemala...

Page 188: ...Pyongyang KR Asia Seoul KW Asia Kuwait KY America Cayman KZ Asia Almaty most locations KZ Asia Qyzylorda Qyzylorda Kyzylorda Kzyl Orda KZ Asia Aqtobe Aqtobe Aktobe KZ Asia Aqtau Atyrau Atirau Gur yev...

Page 189: ...re MX America Mexico_City Central Time most locations MX America Cancun Central Time Quintana Roo MX America Merida Central Time Campeche Yucatan MX America Monterrey Central Time Coahuila Durango Nue...

Page 190: ...America Asuncion QA Asia Qatar RE Indian Reunion RO Europe Bucharest RS Europe Belgrade RU Europe Kaliningrad Moscow 01 Kaliningrad RU Europe Moscow Moscow 00 west Russia RU Europe Volgograd Moscow 0...

Page 191: ...T Africa Sao_Tome SV America El_Salvador SY Asia Damascus SZ Africa Mbabane TC America Grand_Turk TD Africa Ndjamena TF Indian Kerguelen TG Africa Lome TH Asia Bangkok TJ Asia Dushanbe TK Pacific Faka...

Page 192: ...erry County US America Indiana Petersburg Central Time Indiana Pike County US America Menominee Central Time Michigan Dickinson Gogebic Iron Menominee Counties US America North_Dakota Center Central T...

Page 193: ...zone Comments VN Asia Saigon VU Pacific Efate WF Pacific Wallis WS Pacific Apia YE Asia Aden YT Indian Mayotte ZA Africa Johannesburg ZM Africa Lusaka ZW Africa Harare Appendix D Worldwide time zone...

Page 194: ...168 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...

Page 195: ...s with limited vision use the ProtecTIER Manager installation wizard and software After preparing the ProtecTIER Manager workstation for accessibility you can use Windows based screen reader software...

Page 196: ...run Java based applications Procedure 1 Go to http www java com The Java website opens The java com website auto detects the operating system and Internet browser of the computer you use when you acc...

Page 197: ...then click Access Bridge 3 Scroll down to the Java Access Bridge for Microsoft Windows Operating System x x x where x x x is the most recent version listed section Click the Download Java Access Brid...

Page 198: ...l completely Procedure 1 If your workstation is configured to automatically open DVDs temporarily disable the Windows AutoPlay feature for the CD DVD device Use the Windows Help or other Windows docum...

Page 199: ...ecTIER Manager v To change the contrast mode for ProtecTIER Manager go to Enabling the Windows High Contrast option To customize the color palette go to Customizing the color palette on page 178 Enabl...

Page 200: ...ings The Settings for High Contrast dialog box displays as shown in Figure 63 on page 175 ts760898 Figure 62 Display tab 174 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation R...

Page 201: ...able color schemes b Select the high contrast scheme that you want to use c Click Ok to close the Settings for High Contrast dialog box d Click Ok to close the Accessibility Options dialog box After a...

Page 202: ...pens as shown in Figure 64 2 On the toolbar click Tools Preferences The Preferences dialog box opens with the Appearance tab selected as shown in Figure 65 on page 177 ts760899 Figure 64 ProtecTIER Ma...

Page 203: ...ecTIER Manager When the ProtecTIER Manager window opens the display reflects the contrast change as shown in Figure 66 5 Proceed as appropriate v If you want to change one or more of the colors used i...

Page 204: ...opens with the Swatches tab selected as shown in Figure 67 The color that is currently defined for your selection is shown in the Preview pane 4 Select a new color from the color palette i You can als...

Page 205: ...log in to ProtecTIER Manager and add a node the display reflects your custom color selections An example of the default color versus a custom color for Allocable resources is shown in Figure 68 9 Proc...

Page 206: ...180 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...

Page 207: ...ITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or i...

Page 208: ...them as completely as possible the examples include the names of individuals companies brands and products All of these names are fictitious and any similarity to the names and addresses used by an a...

Page 209: ...of others Electronic emission notices This section contains the electronic emission notices or statements for the United States and other countries Federal Communications Commission statement This ex...

Page 210: ...e adequate measures Responsible Manufacturer International Business Machines Corp New Orchard Road Armonk New York 10504 914 499 1900 European community contact IBM Deutschland GmbH IBM Technical Regu...

Page 211: ...inie 2004 108 EG in der Bundesrepublik Deutschland Zulassungsbescheinigung laut dem Deutschen Gesetz ber die elektromagnetische Vertr glichkeit von Ger ten EMVG bzw der EMC EG Richtlinie 2004 108 EG f...

Page 212: ...on IBM Taiwan Corporation 3F No 7 Song Ren Rd Taipei Taiwan Tel 0800 016 888 Japan Voluntary Control Council for Interference VCCI Class A Statement Japan Electronics and Information Technology Indust...

Page 213: ...Korean Communications Commission KCC Class A Statement Russia Electromagnetic Interference EMI Class A Statement rusemi Notices 187...

Page 214: ...188 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...

Page 215: ...el adapters 14 ProtecTIER 101 RAS 151 using IMM connection 151 Configuring IP interfaces 114 connection between TSSC and server 75 console network settings work sheet 143 D date and time changing 117...

Page 216: ...ation xvii sending comments xxiv server battery calibrating 94 server configuration 104 servers powering up components 69 service xx ship group hardware disk configuration script CD 2 publications CD...

Page 217: ......

Page 218: ...Part Number 95P8310 Printed in USA or Mexico GA32 0920 02 1P P N 95P8310...

Reviews: