![background image](http://html1.mh-extra.com/html/ibm/ts7650-protectier-deduplication-appliance/ts7650-protectier-deduplication-appliance_installation-roadmap-manual_4132400123.webp)
5.
Choose one of the following options:
v
If you just performed the preceding steps on server A in scenario
1
or
2
from Table 33 on page 94, continue to the next section of this installation
procedure.
v
If you just performed the preceding steps on server A in scenario
3
or
4
from Table 33 on page 94, repeat them for server B.
v
If you just performed the preceding steps on server B in scenario
3
,
4
,
5
, or
6
from Table 33 on page 94, continue to the next section of this
installation procedure.
Testing Call Home
This section describes how to test the Call Home function.
About this task
The TS7650 supports four types of Call Home activity:
v
Error Initiated Call Home – Triggered by failures on a TS7650 Appliance server
v
Heartbeat/MRPD Call Home – Regularly scheduled calls to report system status,
aliveness, and configuration of the server
v
Test Call Home – Triggered from the RAS command line to test the path to the
IBM Customer Configuration Profile File (CCPF) system.
v
User Initiated Call Home – Triggered from the TSSC GUI to collect a product
engineering (PE) package
Completion of this task is not strictly necessary for successful installation of the
appliance; however, IBM encourages customers to enable Call Home for most
situations, and this task should be completed for those customers who do so.
Procedure
Perform the following steps to run the Call Home test.
1.
Log in to the single server in a stand-alone configuration, or either Server A or
B in a clustered configuration, with the user name:
root
and password:
admin
2.
To complete Call Home enablement and test Call Home by using the
ProtecTIER menu:
a.
At the command line, type
menu
and then press Enter. The ProtecTIER
Service menu displays.
----------------------------------------------------------------------
ProtecTIER Service Menu running on rasap1
----------------------------------------------------------------------
1) ProtecTIER Configuration (...)
2) Manage ProtecTIER services (...)
3) Health Monitoring (...)
4) Problem Alerting (...)
5) Version Information (...)
6) Generate a service report
7) Generate a system view
8) Update ProtecTIER code
E) Exit
----------------------------------------------------------------------
>>> Your choice?
b.
Type the numeral corresponding to
Problem Alerting
and press Enter. The
Problem Alerting menu displays.
Chapter 6. Enabling ProtecTIER RAS functions
97
|
|
|
Summary of Contents for TS7650 PROTECTIER DEDUPLICATION APPLIANCE
Page 8: ...viii IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 12: ...xii IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 14: ...xiv IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 18: ...xviii IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 26: ...xxvi IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 126: ...100 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 152: ...126 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 162: ...136 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 164: ...138 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 194: ...168 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 206: ...180 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 214: ...188 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 217: ......
Page 218: ...Part Number 95P8310 Printed in USA or Mexico GA32 0920 02 1P P N 95P8310...