Note:
This is the preferred connection method. If you do not have access to a USB
keyboard and monitor, you must connect to the IMM by using the procedure in
“Using the TSSC or a service notebook.”
Procedure
Perform the following steps to change the IMM IP address.
1.
Connect a USB keyboard and graphics-capable monitor to Server B.
2.
Log in to the server with the ID:
root
and the password:
admin
.
3.
On the command line, type
reboot
and press Enter.
4.
When the IBM logo displays, press F1 to enter
Setup
mode.
5.
Select
System Settings
>
Integrated Management Module
>
Network
Configuration
.
6.
Locate the current IMM IP address and proceed to define the static IMM IP
address.
7.
For the
Static IP Address
, change the last octet to an address value that is
lower than the default of 254.
For example:
172.31.1.253
.
8.
For the
Netmask
, enter:
255.255.255.0
.
9.
Leave the
Gateway
field blank.
10.
Ensure that use of the
static IP address
is specified.
11.
Select
Save the Network Changes
and then press Enter.
12.
Press
Esc
.
13.
Select
Save Settings
.
14.
Select
Exit Setup
.
The server reboots and the IMM IP address for Server B is now unique.
15.
Return to the procedure that sent you here.
Using the TSSC or a service notebook
This section provides an alternative procedure to connect to the IMM.
Procedure
Perform the following steps to use the TSSC or a service laptop to connect to the
IMM in the ProtecTIER server.
1.
If you are using the TSSC, skip ahead to step 10 on page 153. Otherwise,
continue with step 2.
2.
Connect an Ethernet cable from the Ethernet port on your notebook to the SYS
MGMT (IMM port) on Server B. See Figure 58 on page 153.
152
IBM System Storage TS7650 ProtecTIER Deduplication Appliance: Installation Roadmap Guide
Summary of Contents for TS7650 PROTECTIER DEDUPLICATION APPLIANCE
Page 8: ...viii IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 12: ...xii IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 14: ...xiv IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 18: ...xviii IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 26: ...xxvi IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 126: ...100 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 152: ...126 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 162: ...136 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 164: ...138 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 194: ...168 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 206: ...180 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 214: ...188 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide...
Page 217: ......
Page 218: ...Part Number 95P8310 Printed in USA or Mexico GA32 0920 02 1P P N 95P8310...