Page 3-25
FUNCTIONS
3
Machine Adjustment
3-4-8
Output Check
This is used to check the states of the valves which are used frequently in adjustment for each
stage and work each of them alone.
Solenoid Display
Nozzle
You can work each valve of compulsory blow
and vacuum.
Conveyor
You can work the board positioning of the
board holder, side clamp and upper/lower
clamp.
Head A / Head B
Works the vacuum valve of the head.
Display for Each Address
• The states of the output addresses the ma-
chine uses are displayed with names for each
bit.
Highlighted name shows its bit is ON (1).
When you press the “Name” button with
UNLOCK
pressed, the signal opposite to the current
state is output and displayed again.
Call by No
Displays the address that includes the speci-
fied No. at the left side of screen.
Address
Solenoid
4H4C-E-OMA03-A01-05