ENGLISH
MOBILE WELDER OC PLUS
36
ORBITALUM TOOLS GmbH
, D-78224 Singen www.orbitalum.com
7.8
Operation of the power supply with other mains voltages
The welding power supply is designed for operation on a single-phase mains voltage of 115 V or
230 V AC.
With an input voltage of < 200 V AC, the welding current is limited to max. 120 A due to the higher input
currents.
Welding programs with current values > 120 A cannot be started.
7.9
Connecting the power cable
WARNING
The danger of an electric shock exists through non-compatible or
damaged connectors.
Death or severe injuries can result
► Do not use adapter plugs together with protectively grounded power
tools.
► Ensure that the connecting plug of the machine fit into the outlet.
► When connecting, use a standards-compliant residual-current circuit
breaker rated at 30 mA.
WARNING
Risk of electric shock from faulty or damaged insulation.
Normally protected parts of the power supply (e.g. housing) may be live.
If touched, death or severe injuries can result.
► Check the housing, power cable and protective insulation of all other
cables for proper condition.
1. Plug the cable socket of the power cable (1) included in the scope of delivery into the mains input
socket (2) on the rear of the power supply.
2. Ensure that the yellow cable socket latch (3) is engaged.
3. Connect the power plug to the mains.
2
3
1
Summary of Contents for MOBILE WELDER OC PLUS
Page 8: ...ENGLISH MOBILE WELDER OC PLUS 8 ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com ...
Page 20: ...ENGLISH MOBILE WELDER OC PLUS 20 ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com ...
Page 177: ...MOBILE WELDER OC PLUS ENGLISH ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com 177 ...
Page 200: ...SPARE PARTS MOBILE WELDER OC PLUS 200 ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com ...
Page 204: ......