8.1.4.2.4 Pool Formation
All welding procedure parameters that affect the basic adjustments for pool formation and filler wire
can be adjusted in the "Pool Formation" section of the welding procedure.
28
29
30
31
32
Illustration: "Pool Formation" section of the procedure
NO.
PARAMETER
FUNCTION
28
"Rotor Start De-
lay"
Time period in seconds between ignition and the programmed time in Level
1 in which the welding current builds up linearly. The pool formation
process is static without rotation movement.
29
"Wire Feed"
ON/OFF
Activates/deactivates cold wire feed to the weld head.
NOTICE! This function is only supported by weld heads with a built-in
cold wire unit. When weld heads without a cold wire unit are used, the
following parameters are hidden.
• Wire start delay:
• Wire final delay time:
• Wire retract:
Wire feed ON
Wire feed active
Wire feed OFF
Wire feed not active
30
"Wire Start De-
lay"
Time period in seconds between arc ignition and start of wire feeding.
31
"Wire Final De-
lay Time"
Time period in seconds during which the cold wire still needs to be con-
veyed after completion of the last level.
Summary of Contents for MOBILE WELDER OC PLUS
Page 8: ...ENGLISH MOBILE WELDER OC PLUS 8 ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com ...
Page 20: ...ENGLISH MOBILE WELDER OC PLUS 20 ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com ...
Page 177: ...MOBILE WELDER OC PLUS ENGLISH ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com 177 ...
Page 200: ...SPARE PARTS MOBILE WELDER OC PLUS 200 ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com ...
Page 204: ......