Service and maintenance
10.1
Service screen
See the chapter
.
10.2
Software information
See the chapter
See the chapter
See the chapter
10.3
Motor calibration
During motor calibration, the rotational speed of the weld head is measured and compared with the set
speed.
A deviation can be compensated by the software.
If several weld heads of the same type are used, it is recommended that you perform a motor calibration
each time the weld head is changed.
CAUTION
Coolant leakage during weld head change
Irritation of skin, eyes and respiratory tract possible on contact with
coolant.
► When changing the weld head, switch off the coolant pump and
power supply.
If several weld heads of different types or if all of the same weld heads are identical, this is not neces-
sary because the machine stores one deviation per head type.
Preparation
► Connect the weld head to the power supply- see the operating instructions for the weld head.
Procedure
1. Press the "Motor Calibration" button.
ð
The weld head rotor moves to the home position and then performs a complete revolution.
The required time is measured and compared with the setpoint. The deviation is displayed as
a percentage. Properly calibrated heads generally mean deviations of +/- 2 %.
Summary of Contents for MOBILE WELDER OC PLUS
Page 8: ...ENGLISH MOBILE WELDER OC PLUS 8 ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com ...
Page 20: ...ENGLISH MOBILE WELDER OC PLUS 20 ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com ...
Page 177: ...MOBILE WELDER OC PLUS ENGLISH ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com 177 ...
Page 200: ...SPARE PARTS MOBILE WELDER OC PLUS 200 ORBITALUM TOOLS GmbH D 78224 Singen www orbitalum com ...
Page 204: ......