Summary of Contents for YDAB-01

Page 1: ...User Manual Alarm Button YDAB 01 also covers models YDAB 01N YDAB 01R Firmware version 1 08 2022...

Page 2: ...B 01 002 May 24 2022 Web http www yachtd com NMEA 2000 is a registered trademark of the National Marine Electronics Association SeaTalk NG is a registered trademark of Raymarine UK Limited Garmin is a...

Page 3: ...Strings 16 VI Control from a MFD with CZone Support 25 VII Built in LED Signals 26 VIII Firmware Updates 27 Appendix Troubleshooting 29 Appendix B List of Sound Signals 31 Appendix C List of External...

Page 4: ...larm and LED flashing sequence Channels and corresponding sound alarms can be turned ON or OFF from other equipment including our smart sensors or from the screen of a modern chart plotter Press the c...

Page 5: ...ost of equipment installation and configuration neither shipping the defective Device to the manufacturer 5 Responsibility of the manufacturer in case of any damage as a consequence of Device operatio...

Page 6: ...ls containing an R in the suffix of the model name are equipped with NMEA 2000 connectors and are compatible with Raymarine SeaTalk NG Models containing N in the suffix are equipped with NMEA 2000 Mic...

Page 7: ...o amplifier output 8 Ohm load at 13V 10 W Load Equivalency Number 20 LEN Built in current limiting resistor for the external LED 200 Ohm External LED power supply 3 3 V Operating temperature range 40...

Page 8: ...8 II Device overview Figure 2 Functional scheme...

Page 9: ...Raymarine do not react on MOB message if MOB event with the same MMSI number has being already received but was cancelled earlier Unlike a VHF distress button or activation of EPIRB the signal is not...

Page 10: ...erature pressure and humidity sensors from Yacht Devices can be set up to turn target digital switching equipment channels ON or OFF when the measured value is too high or too low For example the Digi...

Page 11: ...lashing sequence for each event using YD LINK command see the Section V To disable or enable the event use YD EVENT command If different events occur at the same time event with lowest number will hav...

Page 12: ...12 III Device Installation and Connection to NMEA 2000 Figure 3 Device connection...

Page 13: ...stallation requirements SeaTalk NG Reference Manual 81300 1 for Raymarine networks Technical Reference for Garmin NMEA 2000 Products 190 00891 00 for Garmin networks Note that Device is powered from t...

Page 14: ...n Figure 4 It is mandatory to crimp contacts soldering is optional Soldering joints must be protected from the environment with paint or lacquer 3 Connection of the sound speaker Device has a built in...

Page 15: ...programming or wait until the Device enters volume programming after that LED signal In mode programming external LED will continuously flash depending on the current mode 1 short flash MOB button mod...

Page 16: ...o leave notes or contact information This can be done with professional PC software with a hardware gateway to NMEA 2000 network and it may be supported by some models of chart plotters Please refer t...

Page 17: ...so allows you to modify the NMEA 2000 device instance by entering a value in the dedicated field After entering the Device Instance value Figure 1 Address Claim settings group click the Update button...

Page 18: ...specific format mono 16 bit PCM WAV files with sample rate of 22050 Hz and length from 0 1 to 13 seconds from 4 to 688 kBytes Yes the slot size is limited and you will not able to upload your favouri...

Page 19: ...19 Figure 6 Audio files uploading Full list of commands is given in Table 1 Parameters in square brackets can be omitted to get the current setting value from the Device...

Page 20: ...ort in milliseconds Values from 50 to 60 000 1 minute are allowed OFF or 0 disables PGN transmission Commands available in all modes YD MODE MOB DS ENGINE YD MODE MOB Set operation mode Device will be...

Page 21: ...pecified number This setting is ignored in the MOB mode YD INTERVAL 1 28 0 6000 0 YD INTERVAL 1 0 5 YD INTERVAL 3 60 Set interval in seconds second parameter between sound playbacks for specified even...

Page 22: ...ures required to control loads from chart plotters with CZone support See Section VI for details Table 1 continued YD LIST mmsi YD LIST 338064000 338064001 338064002 YD LIST CLEAR Set list of MMSI num...

Page 23: ...ory default setting is OFF YD TR_TEMP OFF 0 600 0 600 YD TR_TEMP 200 1 YD TR_TEMP OFF The same as above but for transmission oil temperature turns on event 6 Transmission Over Temperature YD RPM OFF 0...

Page 24: ...0 YD OIL_PRES OFF Turn ON event 9 Low Oil Pressure when the engine oil pressure is below value specified in the first parameter during specified number of seconds second parameter 0 turns the event O...

Page 25: ...ymarine MFDs 4 Import the configuration file to the MFD usually from microSD card The only exception is Furuno chart plotters They support uploading of configuration file over NMEA 2000 network only T...

Page 26: ...o get an NMEA 2000 address it will constantly flash RED one second flash with one second intervals 1 Signals in MOB button mode Device flashes once in two seconds RED no GPS data received GREEN GPS po...

Page 27: ...py YDAB01 BIN file to the disk README TXT file inside archive can contain important information regarding the update 1 Click NMEA 2000 Devices item in View menu 2 Click Refresh button see Figure 7 at...

Page 28: ...28 Figure 7 Firmware update of Alarm Button YDAB 01...

Page 29: ...000 devices on the plotter 1 Loose connection in the data circuit Treat Device connector with a spray for cleaning electrical contacts Plug Device into another connector 2 NMEA 2000 physical layer iss...

Page 30: ...n sync with NMEA 2000 digital switching equipment in digital switching mode 1 Wrong bank Check that NMEA 2000 digital switching equipment has the same bank Reconfigure Device with YD BANK command see...

Page 31: ...cy horn sounds 6 Sequence of two chimes low to high frequency 7 Sonar ping 8 Old telephone 9 High frequency beeper 10 Whistle 11 Sequence of two bell rings 12 Mechanical alarm clock 13 Engine order te...

Page 32: ...t 21 Emergency vehicle siren slow 22 Emergency vehicle siren high to low frequency 23 Square wave 2500 Hz 24 Emergency vehicle horn alternating two tones 25 High frequency bell 26 Low frequency buzz 1...

Page 33: ...ms ON 150 ms OFF 100ms ON 1 s OFF 6 Three short flashes followed by long delay 100 ms ON 150 ms OFF 100ms ON 150 ms OFF 100ms ON 1 s OFF 7 One long flash followed by long delay 500 ms ON 1 s OFF 8 Tw...

Page 34: ...5 s OFF 24 One short flash followed by extremely long delay 100 ms ON 7 s OFF 25 One short flash followed by one long flash 100 ms ON 200 ms OFF 400 ms ON 200 ms OFF 26 Two short flashes followed by t...

Page 35: ...n 8 Low Fuel Level 23 Maintenance Needed 24 Low System Voltage 11 Engine Communication Error 22 Low Coolant Level 12 Sub or Secondary Throttle 25 Water Flow 13 Neutral Start Protection 26 Water in Fue...

Page 36: ...Group Function Yes Yes PGN 126464 PGN List Rx Tx Yes PGN 126993 Heartbeat Yes See Note 3 PGN 126996 Product Information Yes PGN 126998 Configuration Information Yes PGN 127233 Man Overboard Notificati...

Page 37: ...ching DS or engine alarm modes NMEA 2000 device class function is 120 Display 140 Alarm Enunciator Note 2 Periodic message with 2 000 ms default interval can be changed in settings see Section V Note...