Section 9 Download
When a system first communicates with pump controllers and terminals, it downloads the configuration
related to each device. If information is changed after communication has been established with a configured
device, the FSC3000
™
will need to download the configuration again.
All configurations can be downloaded by typing:
Download <ENTER>
Device-specific configurations can also be downloaded separately:
Download PCT #
(Leave out # to download all PCTs)
Configure PCT #
Configure PCT # Position #
Set Fueltype – When using DPC and prices are changed, price change on pump
must be performed by using download (type: download PCT)
Download FIT #
(Leave out # to download all FITs)
Configure FIT #
Format Receipt Header
Format Receipt Trailer
Format Receipt Body
Format Display #
Format Keyboard #
NOTE:
When using the preceding commands, the “Download” command must also be used.