15.7 ComdataPOS
As of FSC3000
™
version 1.15a a new Comdata network has been added, referred to as the “ComdataPOS”
network. This is different from the previously supported (and still available) “Comdata” network. The
difference between the two is that the “Comdata” network is designed and supported by Comdata for use at
private terminal fuel locations. It only supports a standard dial-up phone connection, with driver prompts only
configurable on the FSC. It is assumed that all Comdata cards (Comchek and MC Fleet) are unique to the
site in use and managed directly by the site owner.
The new ComdataPOS network is available for use at a site that is open to the public allowing any Comdata
presented card to be processed. This network supports TCP/IP connections with dial-up fallback support and
all driver prompts are host-driven allowing Comdata to provide card specific prompting as needed by the
card holder.
When ComdataPOS is selected from the “SET NETWORK” menu the following table will come into view:
Enter option number or press [RETURN] to exit: 1
NETWORK option settings
NETWORK : ComdataPOS
1 - Location Code..................
Dialup Device Type............. TRT2
Device Type Sub-Id............. 1
2 - Site Name......................
3 - Site City......................
4 - Site State.....................
5 - Redial Attempts................ 1
6 - Connect Time......(Seconds).... 30
7 - Local Authorization............ Disabled
8 - Network System................. ON
ON............................. 12:00 AM
OFF............................ 12:00 AM
9 - Authorization Message.......... ^0^FHAVE A SAFE TRIP
10 - Re-Prompt Time....(Minutes).... 10
11 - Communication Parameters....... 2400 7E1 T60Y
12 - Process USA Market MC? ........ NO
Process Canadian Market MC? ... NO
Enter option number or press [RETURN] to exit:
1. Location Code
Option 1. Under ComdataPOS three pieces of information are configurable, but only the first value should be
entered. This is the “Location Code” which is a 5 character entry provided by Comdata when you sign up for
processing. The other two values, “Dialup Device Type” and “Device Type Sub-Id” are configured by default
and should not be changed unless specifically directed by Comdata to do so. When configuring the location
code from the command line, enter the five character location code provided by Comdata and then press
enter three (3) times to skip over the other two entries.
TIP:
If you mistakenly delete or change the device type values and processing to Comdata
fails, reenter them to the values shown above.
Doc. No.: M00-051.00 Rev.: 10
Page 149 of 181
Summary of Contents for M00-051.00 FSC3000
Page 60: ...Doc No M00 051 00 Rev 10 Page 60 of 181...
Page 63: ...Doc No M00 051 00 Rev 10 Page 63 of 181...
Page 69: ...Doc No M00 051 00 Rev 10 Page 69 of 181...
Page 99: ...Doc No M00 051 00 Rev 10 Page 99 of 181...
Page 129: ...Petrol Training Screens Doc No M00 051 00 Rev 10 Page 129 of 181...
Page 130: ...CNG Training Screens Doc No M00 051 00 Rev 10 Page 130 of 181...
Page 181: ......