6.14
Setting the lubricating oil quantity at the central lubrication system
WGKX-1
6.14.1 WGKX-4 and WGKX-5
Setting parameters - 1. Interval time - 2. Running time
Determining the setting status.
Press the "Enter" key and
or
at the same time; the LED and the sequencer lamp
now flash.
1. Change the interval time setting (minutes).
Press the
buttons to change the interval time; confirm the changes by pressing
"Enter".
The interval time set in minutes is shown by the LEDs.
Press the "Enter" key to confirm.
2. Set the running time (seconds).
Press the
buttons to change the running time; confirm the changes by pressing
"Enter".
The running time set in seconds is shown by the LEDs.
Press the "Enter" key to confirm.
All parameters are stored on pressing the "Enter" button.
This completes the setting for the
WGKX-4
control; the control starts to boot.
In the sequence, the
WGKX-5
control now waits for the operating mode setting to be input. The
operating mode is set by selecting the status of the yellow LED and confirmed by pressing the
"Enter" button.
DRB-215Y Panel
DRB-225Y Panel
Pump operational, lights up green
Pump not operational, display no longer
lights up
Readiness for operation,
lights up red
Switch pump on manually
Alarm display
Time programming
LED status - minutes or seconds
128 64 32 16
8
4
2
1
LED
minutes
128 64 32 16
8
4
2
1
LED on = 32 + 8 + 4 = 44
minutes