4 Safety Function Blocks
4 - 84
NX-series Safety Control Unit Instructions Reference Manual (Z931)
SF_MutingPar_2Sensor Instruction Application Example with Two Reflective
Light Barriers
Order
Diagram
Description
1
If reflection light barriers are used as muting
sensors, they are generally arranged diago-
nally. In general, this arrangement of reflec-
tion light barriers as muting sensors requires
only two light barriers, and only
S_MutingSwitch11
(MS_11) and
S_MutingSwitch12
(MS_12) are allocated.
MS_11
MS_12 Receiver
Transmitter
Danger
zone