![background image](http://html1.mh-extra.com/html/omron/nx-sl-series/nx-sl-series_instruction-and-reference-manual_742411150.webp)
4 Safety Function Blocks
4 - 20
NX-series Safety Control Unit Instructions Reference Manual (Z931)
C041
49217
Reset Error 31
An undetected change to TRUE was detected for
EDM1
and
Reset
or equivalent signals were detected during EDM Error 21
status. (Both
Reset
and
EDM1
changed to TRUE at the same
time.)
Ready
= TRUE
S_EDM_Out
= FALSE
Error
= TRUE
C051
49233
Reset Error 32
An undetected change to TRUE was detected for
EDM2
and
Reset
or equivalent signals were detected during EDM Error 22
status. (Both
Reset
and
EDM2
changed to TRUE at the same
time.)
Ready
= TRUE
S_EDM_Out
= FALSE
Error
= TRUE
C061
49249
Reset Error 33
An undetected change to TRUE was detected for
EDM1,
EDM2,
and
Reset
or equivalent signals were detected during
EDM Error 23 status. (
Reset, EDM1,
and
EDM2
changed to
TRUE at the same time.)
Ready
= TRUE
S_EDM_Out
= FALSE
Error
= TRUE
C071
49265
Reset Error 41
When EDM Error 31 status was entered, an undetected change
to TRUE in the
Reset
input was detected.
Ready
= TRUE
S_EDM_Out
= FALSE
Error
= TRUE
C081
49281
Reset Error 42
When EDM Error 32 status was entered, an undetected change
to TRUE in the
Reset
input was detected.
Ready
= TRUE
S_EDM_Out
= FALSE
Error
= TRUE
C091
49297
Reset Error 43
When EDM Error 33 status was entered, an undetected change
to TRUE in the
Reset
input was detected.
Ready
= TRUE
S_EDM_Out
= FALSE
Error
= TRUE
C010
49168
EDM Error 11
The
EDM1
signal is not valid during the initial status of the actu-
ator. If
S_OutControl
is enabled when output is not possible,
the
EDM1
signal changes to FALSE.
Ready
= TRUE
S_EDM_Out
= FALSE
Error
= TRUE
C020
49184
EDM Error 12
The
EDM2
signal is not valid during the initial status of the actu-
ator. If
S_OutControl
is enabled when output is not possible,
the
EDM2
signal changes to FALSE.
Ready
= TRUE
S_EDM_Out
= FALSE
Error
= TRUE
DiagCode (hexa-
decimal)
DiagCode
(decimal)
Status name
Status description and output results
Summary of Contents for NX-SL series
Page 8: ...CONTENTS 6 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 28: ...Sections in this Manual 26 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 98: ...2 Standard Functions 2 64 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 104: ...2 Standard Functions 2 70 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 110: ...2 Standard Functions 2 76 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 265: ...I 1 I NX series Safety Control Unit Instructions Reference Manual Z931 Index ...
Page 268: ...I 4 NX series Safety Control Unit Instructions Reference Manual Z931 Index ...
Page 269: ......