FB-specific State Codes (No Error)
DiagCode (hexadecimal)
DiagCode
(decimal)
Status name
Status description and output results
0000
0
Idle
The FB is disabled (default).
Ready
= FALSE
S_GuardLocked
= FALSE
S_UnlockGuard
= FALSE
Error
= FALSE
8000
32768
Guard Closed and
Locked
The guard is locked.
Ready
= TRUE
S_GuardLocked
= TRUE
S_UnlockGuard
= FALSE
Error
= FALSE
8001
32769
Init
The FB was activated and started.
Ready
= TRUE
S_GuardLocked
= FALSE
S_UnlockGuard
= FALSE
Error
= FALSE
8003
32771
Wait for Reset
The door is closed and locked and the FB is wait-
ing for the operator to reset the function.
Ready
= TRUE
S_GuardLocked
= FALSE
S_UnlockGuard
= FALSE
Error
= FALSE
8011
32785
Wait for Operator
The FB is waiting for the operator to request
unlocking the guard or resetting the function.
Ready
= TRUE
S_GuardLocked
= FALSE
S_UnlockGuard
= FALSE
Error
= FALSE
8012
32786
Guard Open and
Unlocked
The guard is unlocked and open.
Ready
= TRUE
S_GuardLocked
= FALSE
S_UnlockGuard
= TRUE
Error
= FALSE
8013
32787
Guard Closed but
Unlocked
The guard is unlocked but closed.
Ready
= TRUE
S_GuardLocked
= FALSE
S_UnlockGuard
= TRUE
Error
= FALSE
8014
32788
Safety Return
The
S_SafetyActive
signal was restored and the
FB is waiting for a confirmation response (
Reset
)
from the operator.
Ready
= TRUE
S_GuardLocked
= FALSE
S_UnlockGuard
= FALSE
Error
= FALSE
Summary of Contents for NX-SL series
Page 8: ...CONTENTS 6 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 28: ...Sections in this Manual 26 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 98: ...2 Standard Functions 2 64 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 104: ...2 Standard Functions 2 70 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 110: ...2 Standard Functions 2 76 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 265: ...I 1 I NX series Safety Control Unit Instructions Reference Manual Z931 Index ...
Page 268: ...I 4 NX series Safety Control Unit Instructions Reference Manual Z931 Index ...
Page 269: ......