4 Safety Function Blocks
4 - 120
NX-series Safety Control Unit Instructions Reference Manual (Z931)
FB-specific State Codes (No Error)
C010
49168
Test Error 1
The test time was exceeded in state 8020 (Test
Request).
Ready
= TRUE
S_OSSD_Out
= FALSE
S_TestOut
= TRUE
TestPossible
= FALSE
TestExecuted
= FALSE
Error
= TRUE
C020
49184
Test Error 2
The test time was exceeded in state 8030 (Test
Active).
Ready
= TRUE
S_OSSD_Out
= FALSE
S_TestOut
= TRUE
TestPossible
= FALSE
TestExecuted
= FALSE
Error
= TRUE
DiagCode (hexadecimal)
DiagCode
(decimal)
Status name
Status description and output results
0000
0
Idle
The FB is disabled (default).
Ready
= FALSE
S_OSSD_Out
= FALSE
S_TestOut
= TRUE
TestPossible
= FALSE
TestExecuted
= FALSE
Error
= FALSE
8001
32769
Init
The FB detected an activate signal and the FB is
active.
Ready
= TRUE
S_OSSD_Out
= FALSE
S_TestOut
= TRUE
TestPossible
= FALSE
TestExecuted
= FALSE
Error
= FALSE
8002
32770
ESPE Interrupted 1
The FB detected a safety request. The switch
has not been automatically tested.
Ready
= TRUE
S_OSSD_Out
= FALSE
S_TestOut
= TRUE
TestPossible
= FALSE
TestExecuted
= FALSE
Error
= FALSE
DiagCode (hexadecimal)
DiagCode
(decimal)
Status name
Status description and output results
Summary of Contents for NX-SL series
Page 8: ...CONTENTS 6 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 28: ...Sections in this Manual 26 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 98: ...2 Standard Functions 2 64 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 104: ...2 Standard Functions 2 70 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 110: ...2 Standard Functions 2 76 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 265: ...I 1 I NX series Safety Control Unit Instructions Reference Manual Z931 Index ...
Page 268: ...I 4 NX series Safety Control Unit Instructions Reference Manual Z931 Index ...
Page 269: ......