2 - 39
2 Standard Functions
NX-series Safety Control Unit Instructions Reference Manual (Z931)
Dat
a T
y
p
e Co
nversio
n
In
struc
tion
s
2
IN
T_T
O
_WOR
D
• The input condition depends on whether the output is safety data or standard data. If the condition is
not met, a building error will occur.
• If you set a safety data type variable for the output terminal, set a safety data type variable for the
input terminal as well.
• If you set a standard data type variable for the output terminal, you can set either a safety data type
variable or a standard data type variable for the input terminal.
Precautions for Correct Use